Haier HDU-42CF03/H installation manual Cooling, dehumidifying mode Heating mode

Page 14

Operation

Comfortable Sleep

At night, before going to bed you can press down the SLEEP button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable.

In cooling, dehumidifying mode

In heating mode

Note:

In AUTO mode, unit will run in SLEEP function according to the operation mode.

After setting SLEEP function, it is forbidden to calibrate clock.

If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time is complete.

Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER-ON function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first, the TIMER function can not be set.

SETTING T

SHUT DOWN

 

1 hr

 

1 hr

 

about 3 hrs

 

3 hrs

SLEEP RUN BEGINS

SLEEP RUN STOPS

SLEEP RUN BEGINS

SLEEP RUN STOPS

 

about 6 hrs

 

1 hr

 

1 hr

SETTING T

SHUT DOWN

13

Image 14
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not wash the air conditioner with water Machine is adaptive in following situation Parts and Functions Buttons and display of the wire controller Parts and Functions OperationCool Fan operation Auto RUN, COOL,HEAT and DRY Timer operation Timer ON-OFF Cooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Cooling or heating is not sufficient MalfunctionUnit fails to start Cooling is not sufficientMalfunction Followings are not malfunction Care and Maintenance Points to observeFor Preparation of HeatingHot Keep HOT KEEPis operated in the following casesWhen you change your address or the installation place Is The Unit Installed CorrectlyInstallation place For inspection and maintenanceInstallation Manual For Wire Controller Install wire controllerHint Wire sizeHint Installation Manual For Indoor Unit Safety precautionsChoose installation place Height of ceilingPreparation before installation Hanger bolts installationDrain Piping Installation of indoor unitAdjusting to the levelness Good pipingDrainage Test Installation of air suction and discharging ductProcedures Chosen chart of simple duct Air volumeExamples of improper installation Rotate this switch Operation method of fan controllerRefrigerant pipe R0.4~0.8Installation Manual For Electric Wiring Wiring connectionHaier Group