3.Preparation before installation

(1)The position relation among hoisting screw (unit: mm)

360

250

Down side

Up side

1270

853

1103

794

(2) If necessary, cut the opening installation and checking needed on the ceiling. (If has ceiling)

Before installation, finish the preparation work of all the pipes (refrigerant, drainage) and wire (wire controller connection wire, indoor and outdoor unit connection wire) of indoor unit, so that after installation, they can be immediately connected with outdoor unit.

Cut the opening on the ceiling. Maybe it needs to strengthen the ceiling to keep the ceiling even and flat and prevent the ceiling from vibration. For details, please consult to the builder.

(3) Hanger bolts installation

Use care of the piping direction when the unit is installed.

(Use M10 screw bolt)

In order to bear the weight of the unit, for existed

Hole-in anchor

Hole-in plug

ceiling, using foundation screw bolt, for new ceiling,

 

 

 

 

 

 

using burying embedded screw bolt, burying screw

 

 

 

bolt or spot supplied other parts.

 

 

 

 

 

 

Before going on installation, adjust the gaps with ceiling.

Hanging bolt M10

Insert

Concrete

25

Image 26
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not wash the air conditioner with water Machine is adaptive in following situation Parts and Functions Buttons and display of the wire controller Parts and Functions OperationCool Fan operation Auto RUN, COOL,HEAT and DRY Timer operation Timer ON-OFF Cooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Cooling or heating is not sufficient MalfunctionUnit fails to start Cooling is not sufficientMalfunction Followings are not malfunction Care and Maintenance Points to observeFor Preparation of HeatingHot Keep HOT KEEPis operated in the following casesWhen you change your address or the installation place Is The Unit Installed CorrectlyInstallation place For inspection and maintenanceInstallation Manual For Wire Controller Install wire controller Hint Wire size Hint Installation Manual For Indoor Unit Safety precautionsChoose installation place Height of ceilingPreparation before installation Hanger bolts installationDrain Piping Installation of indoor unitAdjusting to the levelness Good pipingDrainage Test Installation of air suction and discharging ductProcedures Chosen chart of simple duct Air volumeExamples of improper installation Rotate this switch Operation method of fan controllerRefrigerant pipe R0.4~0.8Installation Manual For Electric Wiring Wiring connectionHaier Group