Haier HDU-42CF03/H installation manual Hint, Wire size

Page 23

Installation Manual For Wire Controller

3. Indoor unit wiring

Connect terminals (A,B,C,D) on lower part of wire controller to terminals (A, B,C,D) on PCB of indoor unit.

Hint

When make wiring, please keep a distance between wires and power supply cord.

wiring from here

A B C D

Lower part of wire controller

Upper part of wire controller

Wire size

Cord kind

Shield wire (4 core) (refer to Hint 3,4)

Size

0.33mm2

 

 

Use shielede wires for telecommunication between wire controller and indoor unit; indoor unit and outdoor unit. Ground the shield on one side.

Otherwise misoperation because of noise may occur.

Signal wire is self-provided.

Shielded wire

ground

Hint

Tread surface of the terminal well so that shielding may not contact other part.

4.Replace the upper part of wire controller Be careful not to press the wiring.

Hint

1.Switch box and cord for wiring are not supplied.

2.Don't touch PCB with hand.

22

Image 23
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Make sure the system is grounded Safety PrecautionsDo not wash the air conditioner with water Machine is adaptive in following situation Parts and Functions Parts and Functions Operation Buttons and display of the wire controllerCool Fan operation Auto RUN, COOL,HEAT and DRY Timer operation Timer ON-OFF Cooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Cooling is not sufficient MalfunctionUnit fails to start Cooling or heating is not sufficientMalfunction Followings are not malfunction Points to observe Care and Maintenance HOT KEEPis operated in the following cases For Preparation of HeatingHot KeepFor inspection and maintenance Is The Unit Installed CorrectlyInstallation place When you change your address or the installation placeInstall wire controller Installation Manual For Wire ControllerHint Wire sizeHint Safety precautions Installation Manual For Indoor UnitHeight of ceiling Choose installation placeHanger bolts installation Preparation before installationGood piping Installation of indoor unitAdjusting to the levelness Drain PipingDrainage Test Installation of air suction and discharging ductProcedures Air volume Chosen chart of simple ductExamples of improper installation Operation method of fan controller Rotate this switchR0.4~0.8 Refrigerant pipeWiring connection Installation Manual For Electric WiringHaier Group