Haier HDU-42CF03/H installation manual Installation Manual For Indoor Unit, Safety precautions

Page 24

Installation Manual For Indoor Unit

1. Safety precautions

Please read these "Safety Precautions" first then accurately execute the installation work.

 

 

 

Though the precautionary points indicated herein are divided under two headings,

 

WARNING

 

and

 

, those points which are related to the strong possibility of an

installation done in error

CAUTION

resulting in death or

serious injury are listed in the

WARNING

section. However, there is also a

possibility of serious consequences in relationship to the points listed in

the

 

section as well.

CAUTION

In either case, important safety related information is indicated, so by all means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's manual.

Moreover, ask the customer to keep this sheet together with the owner's manual.

WARNING

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing this countermeasure, consult with the company from which you perchased the equipment, and make the installation accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient, injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit. For electrical work, please see that a licensed electrician executes the work while following the safety standards related to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits are used.

Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated refrigerant (R407C) within the refrigeration cycle.

Rupture and injury caused by abnormal high pressure can result from such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company can result in water leakage, electric shock, fire and refrigerant leakage.

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

23

Image 24
Contents Duct Type AIR Conditioner Table of Contents Disposal of the old air conditioner Safety Precautions Make sure the system is groundedDo not wash the air conditioner with water Machine is adaptive in following situation Parts and Functions Buttons and display of the wire controller Parts and Functions OperationCool Fan operation Auto RUN, COOL,HEAT and DRY Timer operation Timer ON-OFF Cooling, dehumidifying mode Heating mode This series changeover switch is set 1. on 2.OFF 3.OFF 4.OFF Malfunction Unit fails to startCooling or heating is not sufficient Cooling is not sufficientMalfunction Followings are not malfunction Care and Maintenance Points to observeFor Preparation of HeatingHot Keep HOT KEEPis operated in the following casesIs The Unit Installed Correctly Installation placeWhen you change your address or the installation place For inspection and maintenanceInstallation Manual For Wire Controller Install wire controllerWire size HintHint Installation Manual For Indoor Unit Safety precautionsChoose installation place Height of ceilingPreparation before installation Hanger bolts installationInstallation of indoor unit Adjusting to the levelnessDrain Piping Good pipingInstallation of air suction and discharging duct ProceduresDrainage Test Chosen chart of simple duct Air volumeExamples of improper installation Rotate this switch Operation method of fan controllerRefrigerant pipe R0.4~0.8Installation Manual For Electric Wiring Wiring connectionHaier Group

HDU-42CF03/H specifications

Haier HDU-42CF03/H is a cutting-edge air conditioning unit designed to provide optimal cooling and heating solutions for both residential and commercial spaces. Renowned for its innovative features and advanced technologies, this model stands out in the competitive HVAC market.

One of the main features of the Haier HDU-42CF03/H is its impressive cooling capacity of 4.2 kW, making it suitable for medium to large-sized rooms. This capacity allows the unit to maintain a comfortable indoor environment even during the hottest summer months. Additionally, it comes equipped with a heating function, ensuring that users can stay warm during colder seasons, thus providing year-round climate control.

The HDU-42CF03/H incorporates advanced inverter technology. This feature allows the air conditioner to adjust its compressor speed based on the indoor temperature, leading to more efficient power consumption. By maintaining a consistent temperature without unnecessary fluctuations, the inverter technology not only enhances comfort but also reduces energy bills, making it a cost-effective choice for consumers.

Another notable characteristic of this model is its quiet operation. With noise levels as low as 30 dB, the Haier HDU-42CF03/H ensures a peaceful environment, making it ideal for bedrooms, offices, or any space where noise reduction is a priority. This feature is particularly appealing to users who value tranquility while enjoying a comfortable climate.

The unit also features a user-friendly remote control system that allows for easy adjustments from a distance. The intuitive settings enable users to switch between modes, set timers, and modify temperatures without hassle. Furthermore, it includes a programmable timer, giving residents the flexibility to schedule cooling and heating times according to their routines.

In terms of air quality, the Haier HDU-42CF03/H is equipped with a multi-layer filtration system, which effectively removes dust, allergens, and pollutants from the air. This feature not only ensures cleaner air but also promotes better health and well-being for users, particularly for those with respiratory issues.

Lastly, the design of the Haier HDU-42CF03/H is sleek and modern, allowing it to blend seamlessly with various interior styles. Its compact size makes installation straightforward, whether wall-mounted or in a corner setup.

In summary, the Haier HDU-42CF03/H is an exceptional air conditioning unit that combines efficiency, comfort, and modern technology, making it a valuable addition to any home or office. With its inverter technology, quiet operation, user-friendly controls, and excellent air filtration capabilities, it addresses the diverse needs of consumers while ensuring optimal performance and satisfaction.