Haier HSU-18CK13(T3) Air flow direction adjustment, Left and right air flow adjustment manual

Page 11

Operation

(5) Air flow direction adjustment

After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the Fig.

COOL

About 10o

Up and down (Use remote controller)

Press SWING button, vertical flap will move within the range shown in the Fig. Press SWING button stop it at a fixed position.

About 10o

COOL About 45o

HEAT About 60o

HEAT

About 60o

Left and right air flow adjustment (manual)

Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig.

Cautions:

It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.

Cautions:

When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right.

(6) Unit stop

Press ON/OFF button. Only time remains on LCD.

All indicators on indoor unit go out. Vertical flap closes automatically.

Cautions:

Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit.

Hints

As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation.

As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation.

Be careful not to catch a cold when cold air blows downward.

It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue.

More than this, unit's load can be reduced and power consumption cut down as well. So, you'd better set a temp. difference of 3-5 C between indoor and outdoor temp. in COOL mode.

10

Image 11
Contents Split Type Room AIR Conditioner Disposal of the old air conditioner Refrigerating circuit is leak-proof SpecificationsMachine is adaptive in following situation Applicable ambient temperature rangeIndoor Unit Parts and FunctionsHints Buttons and display of the remote controllerClock set HI Auto Remote controllers operation Power failure resumeplease set and apply as necessaryFAN Select operation modeEnjoy yourself by just a gentle press Unit startFan speed selection Select temp. settingCOOL,HEAT and DRY operation Left and right air flow adjustment manual Air flow direction adjustmentTo cancel Timer mode Timer OperationTo cancel Timer mode Brief Introduction to Health Operation Health Mode operationRemoval of the restriction of emergency or test operation Emergency and Test OperationEmergency operation Test operationOperation Cool modeHeat mode Power Failure Resume FunctionMaintenance Never fail to observe the followings MaintenanceBefore asking for service, check the following first Trouble shooting