Haier HSU-18CK13(T3) operation manual Machine is adaptive in following situation

Page 4

Cautions

The machine is adaptive in following situation

1.Applicable ambient temperature range:

 

Indoor

Maximum: D.B / W.B

29oC/19oC

 

Minimum: D.B / W.B

18oC/14oC

Cooling

 

Outdoor

Maximum: D.B

54oC/24oC

 

 

Minimum: D.B

18oC

 

 

 

Indoor

Maximum: D.B

27oC

Heating

Minimum: D.B

15oC

Outdoor

Maximum: D.B / W.B

24oC/18oC

 

Minimum: D.B / W.B

-7oC/-8oC

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F

3.If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.

4.The distance between the indoor unit and the floor should be more than 2m.

5.The wiring method should be in line with the local wiring standard.

6.After installation, the power plug should be easily reached.

7.The waste battery should be disposed properly.

8.The appliance is not intended to use by young children or infirm persons without supervision. 9.Young children should be supervised ensure that they do not play with the appliance. 10.The appliance must be installed on strong enough supporter.

11.The wiring diagram is attached inside the machine.

3

Image 4
Contents Split Type Room AIR Conditioner Disposal of the old air conditioner Specifications Refrigerating circuit is leak-proofApplicable ambient temperature range Machine is adaptive in following situationParts and Functions Indoor UnitClock set Buttons and display of the remote controllerHints HI Auto Power failure resumeplease set and apply as necessary Remote controllers operationSelect operation mode Enjoy yourself by just a gentle pressUnit start FANCOOL,HEAT and DRY operation Select temp. settingFan speed selection Air flow direction adjustment Left and right air flow adjustment manualTimer Operation To cancel Timer modeTo cancel Timer mode Health Mode operation Brief Introduction to Health OperationEmergency and Test Operation Emergency operationTest operation Removal of the restriction of emergency or test operationCool mode Heat modePower Failure Resume Function OperationMaintenance Maintenance Never fail to observe the followingsTrouble shooting Before asking for service, check the following first