Haier HSU-24HEK03/R2, 0010530627 operation manual COOL, DRY mode, Auto fan mode

Page 4

Operation

Sleep Operation

Before going to bed,you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.

Use of SLEEP function

After the unit starts,set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.

Operation Mode

1. In COOL,DRY mode

1 hours after SLEEP mode starts,temp.will become

1OC higher than temp.setting.After another 1 hours, temp.rises by 1OC futher.The unit will run for further 6 hours then stops Temp. is higher than temp. setting so that room temperature won’t be too low for your sleep.

SLEEP operation starts

SLEEP operation stops

 

 

Approx.6hrs

 

1 hr

Rises 1OC

1 hr

Rises 1OC

 

 

Temp.setting

 

Unit stop

In COOL, DRY mode

2. In HEAT mode

1 hours after SLEEP mode starts,temp will become 2OC lower than temp.setting.After another 1 hours,temp decrease by 2OC futher.After more another 3hours,temp.rises by 1OC futher.The unit will run for further 3 hours then stops.Temp.is lower than temp. setting so that room temperature won’t be too high for your sleep.

Temp.setting

Unit stop

1 hr

Decreases 2OC

 

 

1 hr

 

 

Decreases 2OC

 

 

3 hrs

 

3 hrs

Rises 1OC

SLEEP

 

SLEEP

operation starts

operation stops

In HEAT mode

3. In AUTO mode

The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode.

4. In FAN mode

It has no SLEEP function.

5.When quiet sleeping function is set to 8 hours, the quiet sleeping time can not be adjusted. When TIMER function is set , the quiet sleeping function can't be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first, the unit will stop automatically, and the other mode will be cancelled.

Power Failure Resume Function

1.If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running.

2.Note to the power failure resume:

press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds.

POWER/SOFT Operation

(1)POWER Operation

When you need rapid heating or cooling, you can use this function. In COOL mode, fan speed automatically takes high speed of AUTO fan mode. In HEAT mode, fan speed automatically takes medium speed of AUTO fan mode.

(2)SOFT Operation

You can use this function when silence is needed for rest or reading. In SOFT operation mode, fan speed automatically takes low speed

of AUTO fan mode.

Note

During POWER operation, in rapid HEAT or COOL modethe room will show uniform temperature distribution. Long period

SOFT operation will cause effect of not too cool or not too warm. To cancel POWER or SOFT operation

Press POWER/SOFT button again, POWER or SOFT disappears.

4

Image 4
Contents Contents Parts and Functions Press ON/OFF on the remote controller, unit starts Changes as follows Remote controllerPress Button RapidlyCOOL, DRY mode Auto fan mode+2= Products shall not be mixed with unsortedGWP=global warming potential Maintenance Use the timer effectivelyCheck proper InstallationDrainage securely Trouble shooting Componentes y funciones Unidad interior Control remotoUnidad exterior Configuración del relojFuncionamiento Funcionamiento básicoAjuste de la dirección del flujo de aire Control remotoUso durante el sueño Funcionamiento Intenso / SuaveUso del temporizador de encendido / apagado TemporizadorRohs WeeeMantenimiento ApagarPrecauciones Apagar AcciónObligatoria Obligatoria ProhibidoPrecauciones Parti e funzioni Unità interna TelecomandoUnità da esterno Impostazione dellorologioFunzionamento Funzionamento Funzionamento in modalità sospensioneFunzione di recupero da black-out Funzionamento Alimentazione/SoftConformità AI Regolamenti Europei PER I Modelli Manutenzione Per un utilizzo intelligente del condizionatoreTelecomando Unità interna Per la pulizia non usare quanto segueAttenzione Azione ObbligatoriaAzione DivietoSpecifiche La macchina si adatta alla seguenti situazioniUnité intérieure Télécommande Pièces et fonctionsUnité extérieure Réglage de lhorlogeTélécommande UtilisationOpération de base Fonction durgence et testFonction Reprise après panne de courant Fonction veilleFonctionnement ALIMENTATION/ Doux Utilisation de la minuterie Marche Arrêt Conformité DES Modèles À LA Législation EuropéenneMaintenance Télécommande Boîtier intérieurPour une utilisation intelligente du climatiseur Ne pas nettoyer avec les produits suivantsAvertissement Arrêt StricteObligation Obligation InterdictionSpécifications Lappareil est adapté aux situations suivantes

HSU-24HEK03/R2, 0010530627 specifications

The Haier HSU-24HEK03/R2 is a cutting-edge air conditioning unit that combines efficiency, advanced technology, and user-friendly features, making it a popular choice for residential and commercial spaces. Designed to provide superior cooling and heating performance, this model is an excellent addition to any indoor environment, ensuring comfort year-round.

One of the standout features of the HSU-24HEK03/R2 is its impressive cooling capacity of 24,000 BTU, which makes it suitable for larger rooms or open-concept spaces. This powerful cooling system allows it to quickly lower indoor temperatures, ensuring a comfortable atmosphere even during the hottest summer days. Its heating function complements this by providing warmth during colder months, making it a versatile option for climate control.

Energy efficiency is a key characteristic of the Haier HSU-24HEK03/R2. Equipped with advanced inverter technology, this air conditioner optimizes power consumption by adjusting the compressor speed according to the cooling demand. This not only reduces energy bills but also contributes to a more sustainable environment. The unit often boasts a high EER (Energy Efficiency Ratio) rating, indicative of its ability to provide effective cooling with lower energy usage.

The multifunctional remote control enhances user convenience, allowing individuals to easily adjust settings from anywhere in the room. The easy-to-read display provides quick access to temperature settings, timer functions, and modes. Additionally, the unit features an intelligent auto-restart function that retains the last settings after a power interruption, providing seamless operation without constant readjustment.

Moreover, the HSU-24HEK03/R2 is designed to operate quietly, ensuring minimal disruption in daily activities. Its low noise level is especially beneficial for bedrooms, offices, and other quiet spaces where sound sensitivity is a concern.

Another essential feature is the comprehensive air filtration system. The unit is equipped with filters that effectively eliminate dust, allergens, and other airborne particles, ensuring that the air circulated in the room remains clean and healthy. Regular maintenance is also simplified with easy-to-clean, removable filters.

In summary, the Haier HSU-24HEK03/R2 stands out due to its powerful cooling and heating capabilities, energy efficiency, convenient remote operation, and effective air filtration. Its combination of technological advancements and user-friendly features makes it a compelling solution for climate control in various environments.