NW-MS6
SECTION 1
SERVICING NOTES
•NOTE FOR REPLACING THE EEPROM (IC6002)
In case of replacing the EEPROM (IC6002) when repairing this set, it is necessary to write the setting for destination.
When replacing the EEPROM (IC6002), write the setting for destination, referring to “4. TEST MODE, Items to Check in the Test Mode,
•Replacement of
•To check the operation when the MAIN board and SUB board are removed, check it after connecting CN100 on the MAIN board and CN200 on the SUB board with the servicing jig (relay board between the MAIN board and SUB board) as shown below.
MAIN board
SUB board
servicing jig (MAIN/SUB relay board)
console unit
3