Goodman Mfg service manual Cooling Performance Data, GSX130181A

Page 12

12

 

 

 

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

MODEL: GSX130181A* / CA*F1824*6** / ZP16K5E-PFV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

75

 

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

IDB*

 

Airflow

 

59

63

 

67

71

59

63

67

71

 

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

 

MBh

17.6

18.3

 

20.0

-

17.2

17.9

19.6

-

 

16.8

17.4

 

19.1

-

16.4

17.0

 

18.6

-

15.6

16.2

17.7

-

14.4

15.0

16.4

-

 

 

 

 

S/T

0.72

0.60

0.42

-

0.75

0.63

0.43

-

 

0.77

0.64

0.44

-

0.79

0.66

0.46

-

0.82

0.69

0.48

-

0.83

0.69

0.48

-

 

 

 

 

Delta T

17

15

11

-

18

15

12

-

 

18

15

12

-

18

15

12

-

17

15

11

-

16

14

11

-

 

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.26

1.29

1.33

-

1.36

1.38

1.43

-

 

1.44

1.47

1.52

-

1.51

1.54

1.59

-

1.57

1.61

1.66

-

1.63

1.66

1.72

-

 

 

 

 

AMPS

4.6

4.7

4.9

-

5.0

5.1

5.3

-

 

5.4

5.6

5.8

-

5.8

6.0

6.2

-

6.2

6.3

6.6

-

6.6

6.7

7.0

-

 

 

 

 

HI PR

213

230

242

-

239

258

272

-

 

272

293

309

-

310

334

352

-

349

375

396

-

385

415

438

-

 

 

 

 

LO PR

105

112

122

-

111

118

129

-

 

115

123

134

-

121

129

141

-

127

135

147

-

131

140

152

-

 

 

 

 

MBh

17.1

17.7

19.4

-

16.7

17.3

19.0

-

 

16.3

16.9

18.5

-

15.9

16.5

18.1

-

15.1

15.7

17.2

-

14.0

14.5

15.9

-

 

 

 

 

S/T

0.69

0.58

0.40

-

0.71

0.60

0.41

-

 

0.73

0.61

0.42

-

0.76

0.63

0.44

-

0.78

0.65

0.45

-

0.79

0.66

0.46

-

 

 

 

 

Delta T

18

16

12

-

18

16

12

-

 

18

16

12

-

18

16

12

-

18

16

12

-

17

15

11

-

 

70

 

600

KW

1.25

1.28

1.32

-

1.35

1.37

1.42

-

 

1.43

1.46

1.50

-

1.50

1.53

1.58

-

1.56

1.60

1.65

-

1.61

1.65

1.70

-

 

 

 

 

AMPS

4.6

4.7

4.9

-

5.0

5.1

5.3

-

 

5.4

5.5

5.7

-

5.8

5.9

6.1

-

6.1

6.3

6.5

-

6.5

6.7

6.9

-

 

 

 

 

HI PR

211

227

240

-

237

255

269

-

 

270

290

306

-

307

330

349

-

345

372

392

-

382

411

434

-

 

 

 

 

LO PR

104

111

121

-

110

117

127

-

 

114

121

132

-

120

127

139

-

126

134

146

-

130

138

151

-

 

 

 

 

MBh

15.8

16.4

17.9

-

15.4

16.0

17.5

-

 

15.1

15.6

17.1

-

14.7

15.2

16.7

-

14.0

14.5

15.9

-

12.9

13.4

14.7

-

 

 

 

 

S/T

0.66

0.55

0.38

-

0.69

0.57

0.40

-

 

0.71

0.59

0.41

-

0.73

0.61

0.42

-

0.76

0.63

0.44

-

0.76

0.64

0.44

-

 

 

 

 

Delta T

18

16

12

-

19

16

12

-

 

19

16

12

-

19

16

12

-

18

16

12

-

17

15

11

-

 

 

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.22

1.25

1.29

-

1.31

1.34

1.38

-

 

1.39

1.42

1.47

-

1.46

1.49

1.54

-

1.52

1.56

1.61

-

1.57

1.61

1.66

-

 

 

 

 

AMPS

4.5

4.6

4.7

-

4.8

4.9

5.1

-

 

5.2

5.4

5.6

-

5.6

5.7

5.9

-

6.0

6.1

6.3

-

6.3

6.5

6.7

-

 

 

 

 

HI PR

205

220

233

-

230

247

261

-

 

261

281

297

-

298

320

338

-

335

361

381

-

370

398

421

-

 

 

 

 

LO PR

101

107

117

-

106

113

124

-

 

111

118

129

-

116

124

135

-

122

130

141

-

126

134

146

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

17.9

18.5

20.0

21.5

17.5

18.0

19.5

21.0

 

17.1

17.6

19.1

20.5

16.7

17.2

18.6

20.0

15.9

16.3

17.7

19.0

14.7

15.1

16.4

17.6

 

 

 

 

S/T

0.82

0.73

0.56

0.36

0.85

0.76

0.58

0.37

 

0.87

0.78

0.59

0.38

0.90

0.81

0.61

0.39

0.93

0.84

0.63

0.41

0.94

0.84

0.64

0.41

 

 

 

 

Delta T

20

18

15

10

20

19

15

11

 

20

19

15

11

20

19

15

11

20

19

15

11

19

17

14

10

 

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.27

1.30

1.34

1.38

1.37

1.40

1.44

1.48

 

1.45

1.48

1.53

1.58

1.52

1.56

1.61

1.66

1.59

1.62

1.67

1.73

1.64

1.68

1.73

1.79

 

 

 

 

AMPS

4.7

4.8

4.9

5.1

5.1

5.2

5.3

5.5

 

5.5

5.6

5.8

6.0

5.9

6.0

6.2

6.5

6.3

6.4

6.6

6.9

6.6

6.8

7.0

7.3

 

 

 

 

HI PR

216

232

245

255

242

260

275

287

 

275

296

313

326

313

337

356

371

352

379

400

418

389

419

442

461

 

 

 

 

LO PR

106

113

123

131

112

119

130

139

 

116

124

135

144

122

130

142

151

128

136

149

158

133

141

154

164

 

 

 

 

MBh

17.4

17.9

19.4

20.8

17.0

17.5

19.0

20.3

 

16.6

17.1

18.5

19.9

16.2

16.7

 

18.1

19.4

15.4

15.8

17.2

18.4

14.3

14.7

15.9

17.1

 

 

 

 

S/T

0.78

0.70

0.53

0.34

0.81

0.73

0.55

0.35

 

0.83

0.74

0.56

0.36

0.86

0.77

 

0.58

0.37

0.89

0.80

0.60

0.39

0.90

0.80

0.61

0.39

 

 

 

 

Delta T

21

19

16

11

21

19

16

11

 

21

19

16

11

21

20

 

16

11

21

19

16

11

20

18

15

10

 

75

 

600

KW

1.26

1.29

1.33

1.37

1.36

1.38

1.43

1.47

 

1.44

1.47

1.52

1.56

1.51

1.54

 

1.59

1.65

1.57

1.61

1.66

1.71

1.63

1.66

1.72

1.77

 

 

 

 

AMPS

4.6

4.7

4.9

5.1

5.0

5.1

5.3

5.5

 

5.4

5.6

5.8

6.0

5.8

6.0

 

6.2

6.4

6.2

6.3

6.6

6.8

6.6

6.7

7.0

7.2

 

 

 

 

HI PR

213

230

242

253

239

258

272

284

 

272

293

309

323

310

334

 

352

368

349

375

396

414

386

415

438

457

 

 

 

 

LO PR

105

112

122

130

111

118

129

137

 

115

123

134

143

121

129

 

141

150

127

135

147

157

131

140

152

162

 

 

 

 

MBh

16.1

16.5

17.9

19.2

15.7

16.2

17.5

18.8

 

15.3

15.8

 

17.1

18.3

15.0

15.4

 

16.7

17.9

14.2

14.6

15.8

17.0

13.2

13.5

14.7

15.7

 

 

 

 

S/T

0.75

0.68

0.51

0.33

0.78

0.70

0.53

0.34

 

0.80

0.72

 

0.54

0.35

0.83

0.74

0.56

0.36

0.86

0.77

0.58

0.37

0.87

0.78

0.59

0.38

 

 

 

 

Delta T

21

20

16

11

22

20

16

11

 

22

20

 

16

11

22

20

16

11

21

20

16

11

20

18

15

10

 

 

 

525

KW

1.23

1.26

1.30

1.34

1.32

1.35

1.39

1.44

 

1.41

1.43

 

1.48

1.53

1.48

1.51

1.55

1.61

1.54

1.57

1.62

1.67

1.59

1.62

1.67

1.73

 

 

 

 

AMPS

4.5

4.6

4.8

4.9

4.9

5.0

5.2

5.3

 

5.3

5.4

 

5.6

5.8

5.7

5.8

6.0

6.2

6.0

6.2

6.4

6.6

6.4

6.5

6.8

7.0

 

 

 

 

HI PR

207

223

235

245

232

250

264

275

 

264

284

 

300

313

301

324

342

357

338

364

385

401

374

402

425

443

 

 

 

 

LO PR

102

108

118

126

108

114

125

133

 

112

119

 

130

138

117

125

136

145

123

131

143

152

127

135

148

157

 

 

* Entering Indoor Dry Bulb Temperature

 

 

NOTE:

Shaded area is ACCA (TVA)

conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA

GSX130181A*

Image 12
Contents Technical Manual 024 Product IdentificationGSX130363A Product Design AA AADimensions Condensing Unit Specifications 208/230-60-1Or 3/4 GSX13018-601B GSX130181C GSX13036-603,4 VSX130181A VSX130241A VSX130301A VSX130361A VSX130421A VSX130481AVSX13018 & 601B Cooling Performance Data GSX130181ABulb Temperature Model GSX130181AA / CA*F1824*6** / ZP16K5E-PFV105 115 Entering Indoor Wet Bulb Temperature 22.0359 21.3105 115 Entering Indoor Wet Bulb Temperature GSX130241AModel GSX130241AA / CA*F1824*6** / ZP20K5-PFV Airflow 27.1379 132GSX130301A Model GSX130301AA / CA*F3030*6** / ZP24K5E-PFV28.4 400GSX130361A Model GSX130361AA / CA*F4860*6** / ZP31K5E-PFV 35.011.9 39038.2 13.3372 133GSX130421A Model GSX130421AA / CA*F4860*6** / ZP34K5-PFV40.0 13.843.9 15.1136 42.6GSX130481A Model GSX13048-1AA / CA*F4860*6** / ZP39K5E-PFV46.0 15.7GSX130601A Model GSX130601AA / CA*F4860*6**/ ZP51K5E-PFV Cooling Performance Data GSX130181B*/VSX130181A 18.0 Cooling Performance Data GSX130181C*/VSX130181B 16.9140 153 163 Entering Indoor Dry Bulb Temperature 11.7 11.612.8 13.0 13.2 376 397 414Cooling Performance Data GSX130241B*/VSX130241A 22.2363 Cooling Performance Data GSX130301B*/VSX130301A 10.4 10.8 381 410 432 451478 498 136 114 122Cooling Performance Data GSX130361B*/VSX130361A 32.8373 Cooling Performance Data GSX130421B*/VSX130421A 38.041.0 14.7142 Cooling Performance Data GSX130481B*/VSX130481A 16.2 147Cooling Performance Data GSX130601B*/VSX130601B 145 158 168 Entering Indoor Dry Bulb Temperature 20.2 20.9 21.721.4 22.2 23.0 454 479 500KW =Total system power GSX130363ACooling Operation GSX130483A 346380 GSX130484A Cooling Performance Data GSX130603A 52.8399 GSX130604A 391430 Performance Data Performance TestWiring DiagramsWiring Diagrams GSX13018-601B*/GSX130181C* VSX13018-601AVSX130181B GSX13036-603,4A