Goodman Mfg GSX service manual 373

Page 35

MODEL: GSX130361B* / CA*F3036*6C*

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

MBh

32.2

32.9

 

35.1

37.5

31.4

32.1

 

34.3

36.7

30.7

31.3

 

33.5

35.8

29.9

30.6

 

32.7

34.9

28.4

29.1

31.0

33.2

26.3

26.9

28.8

30.7

 

 

S/T

0.87

0.81

0.66

0.49

0.90

0.84

0.69

0.51

0.92

0.86

0.70

0.53

0.95

0.89

0.73

0.54

0.99

0.93

0.75

0.56

1.00

0.93

0.76

0.57

 

1050

Delta T

24

23

20

16

25

24

21

16

25

24

21

16

25

24

21

17

25

24

20

16

23

22

19

15

 

KW

2.43

2.48

2.56

2.64

2.61

2.67

2.75

2.84

2.77

2.83

2.92

3.01

2.91

2.97

3.07

3.17

3.03

3.09

3.19

3.30

3.13

3.20

3.30

3.41

 

 

AMPS

8.9

9.1

9.4

9.8

9.6

9.9

10.2

10.6

10.5

10.7

11.1

11.5

11.2

11.5

11.9

12.3

11.9

12.2

12.6

13.1

12.6

13.0

13.4

13.9

 

 

HI PR

219

235

249

259

245

264

279

291

279

300

317

331

318

342

361

377

358

385

406

424

395

425

449

468

 

 

LO PR

101

108

118

125

107

114

124

132

111

118

129

138

117

124

136

145

123

130

142

152

127

135

147

157

 

 

MBh

34.9

35.6

38.1

40.7

34.0

34.8

37.2

39.7

33.2

34.0

36.3

38.8

32.4

33.1

 

35.4

37.8

30.8

31.5

33.6

36.0

28.5

29.2

31.2

33.3

 

 

S/T

0.90

0.84

0.69

0.51

0.93

0.87

0.71

0.53

0.96

0.90

0.73

0.55

0.99

0.93

 

0.75

0.56

1.00

0.96

0.78

0.58

1.00

0.97

0.79

0.59

80

1200

Delta T

24

23

20

16

24

23

20

16

24

23

20

16

25

23

 

20

16

24

23

20

16

22

22

19

15

KW

2.49

2.54

2.62

2.70

2.68

2.73

2.82

2.91

2.84

2.90

2.99

3.09

2.98

3.05

 

3.14

3.25

3.11

3.17

3.27

3.38

3.21

3.28

3.39

3.50

 

 

AMPS

9.1

9.4

9.7

10.0

9.9

10.1

10.5

10.9

10.8

11.0

11.4

11.8

11.5

11.8

 

12.2

12.7

12.3

12.6

13.0

13.5

13.0

13.3

13.8

14.3

 

 

HI PR

226

243

256

267

253

272

288

300

288

310

327

341

328

353

 

373

389

369

397

419

437

407

438

463

483

 

 

LO PR

105

111

121

129

110

117

128

137

115

122

133

142

121

128

 

140

149

126

134

147

156

131

139

152

162

 

 

MBh

35.9

36.7

39.2

41.9

35.1

35.8

38.3

40.9

34.2

35.0

37.4

40.0

33.4

34.1

 

36.5

39.0

31.7

32.4

34.6

37.0

29.4

30.0

32.1

34.3

 

 

S/T

0.94

0.88

0.72

0.54

1.00

0.92

0.75

0.56

1.00

0.94

0.76

0.57

1.00

0.97

0.79

0.59

1.00

1.00

0.82

0.61

1.00

1.00

0.83

0.62

 

 

Delta T

23

22

19

15

24

22

19

16

23

22

19

16

23

23

20

16

22

22

19

15

20

20

18

14

 

1350

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

2.51

2.56

2.64

2.72

2.70

2.75

2.84

2.93

2.86

2.92

3.01

3.11

3.01

3.07

3.17

3.27

3.13

3.20

3.30

3.41

3.24

3.31

3.42

3.53

 

 

AMPS

9.2

9.5

9.8

10.1

10.0

10.2

10.6

11.0

10.9

11.1

11.5

11.9

11.6

11.9

12.3

12.8

12.4

12.7

13.1

13.6

13.1

13.5

13.9

14.5

 

 

HI PR

228

245

259

270

256

275

290

303

291

313

330

345

331

356

376

392

372

401

423

441

412

443

468

488

 

 

LO PR

106

112

123

131

112

119

130

138

116

123

135

143

122

130

141

151

128

136

148

158

132

140

153

163

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

32.7

33.4

34.9

37.3

32.0

32.6

34.1

36.4

31.2

31.8

33.3

35.6

30.5

31.0

32.5

34.7

28.9

29.5

30.9

33.0

26.8

27.3

28.6

30.5

 

 

S/T

0.91

0.88

0.79

0.64

0.94

0.91

0.82

0.67

0.97

0.93

0.84

0.68

1.00

0.96

0.87

0.70

1.00

1.00

0.90

0.73

1.00

1.00

0.91

0.74

 

1050

Delta T

26

26

24

21

26

26

25

21

26

26

25

21

27

26

25

21

25

26

24

21

23

24

23

20

 

KW

2.45

2.50

2.58

2.66

2.63

2.69

2.77

2.86

2.79

2.85

2.94

3.04

2.93

3.00

3.09

3.19

3.05

3.12

3.22

3.33

3.16

3.23

3.33

3.44

 

 

AMPS

9.0

9.2

9.5

9.9

9.7

10.0

10.3

10.7

10.6

10.8

11.2

11.6

11.3

11.6

12.0

12.4

12.0

12.3

12.8

13.2

12.8

13.1

13.5

14.0

 

 

HI PR

221

238

251

262

248

267

282

294

282

303

320

334

321

346

365

381

361

389

411

428

399

430

454

473

 

 

LO PR

102

109

119

127

108

115

126

134

112

120

131

139

118

126

137

146

124

132

144

153

128

136

149

158

 

 

MBh

35.5

36.2

37.9

40.4

34.6

35.3

37.0

39.5

33.8

34.5

36.1

38.5

33.0

33.6

35.2

37.6

31.3

31.9

33.5

35.7

29.0

29.6

31.0

33.1

 

 

S/T

0.94

0.91

0.82

0.67

0.98

0.94

0.85

0.69

1.00

0.97

0.87

0.71

1.00

1.00

0.90

0.73

1.00

1.00

0.93

0.76

1.00

1.00

0.94

0.76

85

1200

Delta T

26

25

24

21

26

26

24

21

26

26

24

21

25

26

24

21

24

24

24

21

22

23

22

19

KW

2.51

2.56

2.64

2.72

2.70

2.75

2.84

2.93

2.86

2.92

3.01

3.11

3.01

3.07

3.17

3.27

3.13

3.20

3.30

3.41

3.24

3.31

3.42

3.53

 

 

AMPS

9.2

9.5

9.8

10.1

10.0

10.2

10.6

11.0

10.9

11.1

11.5

11.9

11.6

11.9

12.3

12.8

12.4

12.7

13.1

13.6

13.1

13.5

13.9

14.5

 

 

HI PR

228

245

259

270

256

275

290

303

291

313

330

345

331

356

376

392

372

401

423

441

412

443

468

488

 

 

LO PR

106

112

123

131

112

119

130

138

116

123

135

143

122

130

141

151

128

136

148

158

132

140

153

163

 

 

MBh

36.5

37.2

39.0

41.6

35.7

36.4

38.1

40.6

34.8

35.5

37.2

39.7

34.0

34.6

36.3

38.7

32.3

32.9

34.5

36.8

29.9

30.5

31.9

34.1

 

 

S/T

0.99

0.95

0.86

0.70

1.00

0.99

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

0.94

0.77

1.00

1.00

0.98

0.80

1.00

1.00

0.99

0.80

 

1350

Delta T

25

24

23

20

24

24

23

20

24

24

23

20

23

24

23

20

22

22

23

20

20

21

21

19

 

KW

2.53

2.58

2.66

2.74

2.72

2.77

2.86

2.95

2.88

2.95

3.04

3.14

3.03

3.10

3.20

3.30

3.16

3.22

3.33

3.44

3.26

3.33

3.44

3.56

 

 

AMPS

9.3

9.5

9.9

10.2

10.1

10.3

10.7

11.1

11.0

11.2

11.6

12.1

11.7

12.0

12.4

12.9

12.5

12.8

13.2

13.8

13.3

13.6

14.0

14.6

 

 

HI PR

230

248

261

273

258

278

293

306

294

316

334

348

334

360

380

396

376

405

427

446

416

447

472

493

 

 

LO PR

107

113

124

132

113

120

131

139

117

125

136

145

123

131

143

152

129

137

150

159

133

142

155

165

 

 

 

 

 

35

* Entering Indoor Dry Bulb Temperature

NOTE: Shaded area is AHRI Rating Conditions

AMPS=outdoor unit amps (comp.+fan)

High and low pressures are measured at the liquid and suction service valves.

KW=Total system power

COOLING PERFORMANCE DATA GSX130361B*/VSX130361A*

Image 35
Contents Technical Manual Product Identification 024GSX130363A AA AA Product DesignDimensions Or 3/4 Condensing Unit Specifications208/230-60-1 GSX13018-601B GSX130181C GSX13036-603,4 VSX130361A VSX130421A VSX130481A VSX130181A VSX130241A VSX130301AVSX13018 & 601B GSX130181A Cooling Performance Data105 115 Bulb TemperatureModel GSX130181AA / CA*F1824*6** / ZP16K5E-PFV 21.3 Entering Indoor Wet Bulb Temperature22.0 359Model GSX130241AA / CA*F1824*6** / ZP20K5-PFV 105 115 Entering Indoor Wet Bulb TemperatureGSX130241A 132 Airflow27.1 379400 GSX130301AModel GSX130301AA / CA*F3030*6** / ZP24K5E-PFV 28.4GSX130361A 390 Model GSX130361AA / CA*F4860*6** / ZP31K5E-PFV35.0 11.9133 38.213.3 37213.8 GSX130421AModel GSX130421AA / CA*F4860*6** / ZP34K5-PFV 40.042.6 43.915.1 13615.7 GSX130481AModel GSX13048-1AA / CA*F4860*6** / ZP39K5E-PFV 46.0GSX130601A Model GSX130601AA / CA*F4860*6**/ ZP51K5E-PFV Cooling Performance Data GSX130181B*/VSX130181A 18.0 16.9 Cooling Performance Data GSX130181C*/VSX130181B376 397 414 140 153 163 Entering Indoor Dry Bulb Temperature11.7 11.6 12.8 13.0 13.222.2 Cooling Performance Data GSX130241B*/VSX130241A363 Cooling Performance Data GSX130301B*/VSX130301A 136 114 122 10.4 10.8381 410 432 451 478 49832.8 Cooling Performance Data GSX130361B*/VSX130361A373 38.0 Cooling Performance Data GSX130421B*/VSX130421A142 41.014.7 Cooling Performance Data GSX130481B*/VSX130481A 147 16.2Cooling Performance Data GSX130601B*/VSX130601B 454 479 500 145 158 168 Entering Indoor Dry Bulb Temperature20.2 20.9 21.7 21.4 22.2 23.0GSX130363A KW =Total system powerCooling Operation 346 GSX130483A380 GSX130484A Cooling Performance Data 52.8 GSX130603A399 391 GSX130604A430 Performance Test Performance DataDiagrams WiringGSX13018-601B*/GSX130181C* VSX13018-601A Wiring DiagramsVSX130181B GSX13036-603,4A