Goodman Mfg service manual GSX130363A

Page 3

PRODUCT IDENTIFICATION

The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information.

GSX130181A*

GSX130363A*

VSX130181A*

GSX130241A*

GSX130483A*

VSX130241A*

GSX130301A*

GSX130484A*

VSX130301A*

GSX130361A*

GSX130603A*

VSX130361A*

GSX130421A*

GSX130604A*

VSX130421A*

GSX130481A*

 

VSX130481A*

GSX130601A*

 

 

 

 

VSX130181B*

GSX130181B*

 

VSX130601B*

GSX130241B*

 

 

GSX130301B*

 

 

GSX130361B*

 

 

GSX130421B*

 

 

GSX130481B*

 

 

GSX130601B*

 

 

GSX130181C*

 

 

* Indicates minor revision & is not used for order entry or inventory management

WARNING

The United States Environmental Protection Agency (“EPA”) has issued various regulations re-

garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow

 

these regulations may harm the environment and can lead to the imposition of substantial fines.

 

These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.

 

 

WARNING

Do not connect or use any device

that is not design certified by Good-

 

man for use with this unit. Serious

property damage, personal injury, reduced unit perfor- mance and/or hazardous conditions may result from the use of such non-approved devices.

WARNING To prevent the risk of property

damage, personal injury, or death, do not store combustible materi- als or use gasoline or other flammable liquids or vapors

in the vicinity of this appliance.

3

Image 3
Contents Technical Manual Product Identification 024GSX130363A AA AA Product DesignDimensions Condensing Unit Specifications 208/230-60-1Or 3/4 GSX13018-601B GSX130181C GSX13036-603,4 VSX130361A VSX130421A VSX130481A VSX130181A VSX130241A VSX130301AVSX13018 & 601B GSX130181A Cooling Performance DataBulb Temperature Model GSX130181AA / CA*F1824*6** / ZP16K5E-PFV105 115 21.3 Entering Indoor Wet Bulb Temperature22.0 359105 115 Entering Indoor Wet Bulb Temperature GSX130241AModel GSX130241AA / CA*F1824*6** / ZP20K5-PFV 132 Airflow27.1 379400 GSX130301AModel GSX130301AA / CA*F3030*6** / ZP24K5E-PFV 28.4GSX130361A 390 Model GSX130361AA / CA*F4860*6** / ZP31K5E-PFV35.0 11.9133 38.213.3 37213.8 GSX130421AModel GSX130421AA / CA*F4860*6** / ZP34K5-PFV 40.042.6 43.915.1 13615.7 GSX130481AModel GSX13048-1AA / CA*F4860*6** / ZP39K5E-PFV 46.0GSX130601A Model GSX130601AA / CA*F4860*6**/ ZP51K5E-PFV Cooling Performance Data GSX130181B*/VSX130181A 18.0 16.9 Cooling Performance Data GSX130181C*/VSX130181B376 397 414 140 153 163 Entering Indoor Dry Bulb Temperature11.7 11.6 12.8 13.0 13.222.2 Cooling Performance Data GSX130241B*/VSX130241A363 Cooling Performance Data GSX130301B*/VSX130301A 136 114 122 10.4 10.8381 410 432 451 478 49832.8 Cooling Performance Data GSX130361B*/VSX130361A373 38.0 Cooling Performance Data GSX130421B*/VSX130421A41.0 14.7142 Cooling Performance Data GSX130481B*/VSX130481A 147 16.2Cooling Performance Data GSX130601B*/VSX130601B 454 479 500 145 158 168 Entering Indoor Dry Bulb Temperature20.2 20.9 21.7 21.4 22.2 23.0GSX130363A KW =Total system powerCooling Operation 346 GSX130483A380 GSX130484A Cooling Performance Data 52.8 GSX130603A399 391 GSX130604A430 Performance Test Performance DataDiagrams WiringGSX13018-601B*/GSX130181C* VSX13018-601A Wiring DiagramsVSX130181B GSX13036-603,4A