CONDENSING UNIT SPECIFICATIONS |
| |||||
| GSX130363A* | GSX130483A* | GSX130484A* | GSX130603A* | GSX130604A* |
|
|
|
|
|
|
|
|
Cooling Capacity, BTUH | 36,000 | 48,000 | 48,000 | 60,000 | 60,000 |
|
Decibels | 74 | 76 | 76 | 77 | 77 |
|
|
|
|
|
|
|
|
Compressor |
|
|
|
|
|
|
R.L. Amps | 10.40 | 13.1 | 6.1 | 15.9 | 7.1 |
|
L.R. Amps | 73.0 | 83.1 | 41.0 | 110.0 | 52.0 |
|
Type | Scroll | Scroll | Scroll | Scroll | Scroll |
|
Condenser Fan Motor |
|
|
|
|
|
|
Horsepower | 1/6 | 1/4 | 1/4 | 1/4 | 1/4 |
|
F.L. Amps | 1.10 | 1.50 | 0.80 | 1.50 | 0.80 |
|
|
|
|
|
|
|
|
Refrigerant System |
|
|
|
|
|
|
Liquid Line, Inches O.D.* | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" |
|
Suction Line, Inches O.D.* | 7/8" | 1 1/8" | 1 1/8" | 1 1/8" | 1 1/8" |
|
Liquid Valve Connection, Inches O.D.* | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" |
|
Suction Valve Connection, Inches O.D.* 3 | 3/4" 3 | 7/8" 4 | 7/8" 4 | 7/8" 4 | 7/8" 4 |
|
Refrigerant Charge | 92.0 | 128.0 | 128.0 | 125.0 | 125.0 |
|
Piston Size | 0.068 | 0.080 | 0.080 | 0.086 | 0.086 |
|
Power Supply |
| |||||
Minimum Circuit Ampacity(1) | 14.1 | 17.9 | 8.4 | 21.4 | 9.7 |
|
Maximum Overcurrent Device(2) | 20 | 30 | 15 | 35 | 15 |
|
Min / Max Volts | 197 / 253 | 197 / 253 | 414 / 506 | 197 / 253 | 414 / 506 |
|
|
|
|
|
|
|
|
Electrical Conduit Size |
|
|
|
|
|
|
Power Supply(Inches) | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 | 1/2 or 3/4 |
|
Approximate Shipping Weight | 196 | 190 | 189 | 197 | 196 |
|
(1)Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)Maximum Overcurrent Protection Device: MUST use time delay fuses or
(3)Installer must supply a 3/4" to 7/8" adapter for suction line connections.
(4)Installer must supply a 7/8" to 1 1/8" adapter for suction line connections.
NOTES:
*Always check the S&R plate for electrical data on the unit being installed.
*Installer will need to supply 7/8" to 1 1/8" adapters for suction line connections.
*Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.
*Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.