Graco 24R200 operation manual Overview, System Description, Power Requirements

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

BURN HAZARD

Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:

Do not touch hot fluid or equipment.

Overview

System Description

The heated platen kit is a field installed kit to add heat to the platen. The additional heat may change the viscosity properties of the material and allow the material to flow easier through the system.

Power Requirements

A 25A (minimum) - 30A (maximum) circuit breaker must be installed on the incoming power supply.

Nominal Voltage**

Wattage

Amps*

 

 

 

240 V

3,500 per Platen

20

 

 

 

*Add to power requirements of ExactaBlend AGP Advanced Glazing Proportioner system. Amps maxi- mum per leg shown.

**190-264 voltage range acceptable.

332511A

3

Image 3
Contents Heated Platen Kit Related Manuals Contents Power Requirements OverviewSystem Description Heated Platen Kit Component Identification70 1 2 Heat ControllerInstallation Access the PlatenGrounding Connect the Ground Wires Install the Heat Coils and the Thermostat SwitchMount the RTD Connect the Power LeadsAttach the Platen Covers Mount the Heat Electrical Panel on the 5 Gallon 19 liter Ram Mount the Junction BoxConnect the Leads in the Junction Box Route the Power Cord and Signal Cable to the Junction BoxInstallation Setup Operation StartupShutdown Platen Maintenance MaintenanceCommon Problems TroubleshootingProblem Cause Verification Solution Replace Platen Heaters and Sensor RepairSchematic Heated Platen Kit, 24R200 PartsParts 332511A Part Description Quantity WASHER, M6 Heat Module Heat Enclosure, 24R870117 130 118 114 124 126 102 104 120 Part Description Quantity Parts 332511A Graco Information Graco Standard Warranty