Graco 24R200 Install the Heat Coils and the Thermostat Switch, Connect the Ground Wires

Page 7

Installation

2. Install the Heat Coils and the Thermostat Switch.

- (1) Thermostat

- (2) Washers

- (2) Screws

- (6) 1/4-20 Studs

- (6) Flat Washers

-(6) Lock Washers

-(6) Nuts

3.Connect the Ground Wires.

Connect the ground wires to the terminal lug and to the platen covers (not shown in view). Attach the conduit to the platen cover and route the wires through the conduit when connections are complete.

- (3) Ground Wires

- (2) Lock Washers

- (2) Nuts

- (1) Terminal Lug

332511A

7

Image 7
Contents Heated Platen Kit Related Manuals Contents Overview Power RequirementsSystem Description Heated Platen Kit Component Identification70 1 2 Heat ControllerAccess the Platen InstallationGrounding Connect the Ground Wires Install the Heat Coils and the Thermostat SwitchMount the RTD Connect the Power LeadsAttach the Platen Covers Mount the Heat Electrical Panel on the 5 Gallon 19 liter Ram Mount the Junction BoxConnect the Leads in the Junction Box Route the Power Cord and Signal Cable to the Junction BoxInstallation Setup Startup OperationShutdown Platen Maintenance MaintenanceCommon Problems TroubleshootingProblem Cause Verification Solution Replace Platen Heaters and Sensor RepairSchematic Heated Platen Kit, 24R200 PartsParts 332511A Part Description Quantity WASHER, M6 Heat Module Heat Enclosure, 24R870117 130 118 114 124 126 102 104 120 Part Description Quantity Parts 332511A Graco Information Graco Standard Warranty