Lennox International Inc Elite Series Gas Furnace, EL296UHE Side View, Front View, Top View

Models: EL296UHE Elite Series Gas Furnace

1 58
Download 58 pages 51.32 Kb
Page 31
Image 31
Side View

2” EXTENSION FOR 2” PVC PIPE1” EXTENSION FOR 3”

PVC PIPE

4''

FURNACE

INTAKE

PIPE

FLAT

SIDE

FURNACE

EXHAUST

PIPE

GLUE EXHAUST

END FLUSH INTO

TERMINATION

1-1/2” ACCELERATOR

(all -45, -070 and -090 units)

EXHAUST

 

12”

 

(305MM)

VENT

 

5”

5-1/2”

 

(127MM)

(140mm)

INTAKE

 

 

AIR

 

 

 

18” MAX.

Front View

 

(457MM)

 

EXHAUST VENT

 

 

 

 

 

12” (305MM) Min.

 

 

 

 

 

 

above grade or

Inches (MM)

 

 

 

 

 

average snow

 

 

 

INTAKE

 

accumulation.

 

 

 

 

 

 

 

 

 

AIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

optional intake elbow

FLUSH-MOUNT SIDE WALL TERMINATION

51W11 (US) or 51W12 (Canada)

 

FIGURE 38

 

 

 

 

 

1 1/2” (38mm) accelerator

EXHAUST

 

provided on 71M80 & 44W92

 

kits for EL296UH045E36B, &

VENT

 

070E36B

 

Side View

OPTIONAL VENT TERMINATION FOR MULTIPLE UNIT

INSTALLATION OF DIRECT VENT WALL TERMINATION KIT

(22G44, 44J40, 30G28 or 81J20)

 

FIGURE 41

Front View

EXHAUST VENT

 

SIZE

 

TERMINATION

12” (305mm)

Minimum

Above Average

FLASHING

INTAKE (Not Furnished)

AIR

INTAKE

PIPE PER

TABLE 8.

AIR

 

Snow

Accumulation

CLAMP

SHEET METAL STRAP

(Clamp and sheet metal strap

must be field installed to support

the weight of the termination kit.)

FIELD-PROVIDED

REDUCER MAY BE REQUIRED

TO ADAPT LARGER VENT PIPE SIZE TO TERMINATION

Top View

1/2” (13MM) Foam Insulation in Unconditioned Space

FIELD-

PROVIDED

REDUCER MAY

BE REQUIRED

TO ADAPT

LARGER VENT

PIPE SIZE TO

TERMINATION

EXHAUST VENT

INTAKE AIR

6 (152MM) MIN.

OUTSIDE WALL

DIRECT VENT CONCENTRIC ROOFTOP TERMINATION

71M80, 69M29 or 60L46 (US) 44W92 or 44W93 (Canada)

FIGURE 39

FIELD-PROVIDED

1-1/2” (38mm) accelerator

REDUCER MAY BE REQUIRED

provided on 71M80 & 44W92

TO ADAPT LARGER VENT

kits for EL296UH045E36B, &

PIPE SIZE TO TERMINATION

 

070E36B

 

 

 

 

OUTSIDE

INTAKE

 

WALL

 

AIR

 

EXHAUST

 

 

 

 

EXHAUST

VENT

 

 

VENT

INTAKE

CLAMP

INTAKE 12” (305mm) Min.

AIR

above grade or

AIR

(Not Furnished)

 

average snow

 

 

 

accumulation.

 

 

 

GRADE

DIRECT VENT CONCENTRIC WALL TERMINATION

 

71M80, 69M29 or 60L46 (US)

 

 

44W92 or 44W93 (Canada)

 

FIGURE 40

DIRECT VENT WALL TERMINATION KIT

(30G28 or 81J20)

FIGURE 42

Front View

EXHAUST VENT

 

SIZE

 

TERMINATION

 

PIPE PER

 

TABLE 8.

INTAKE

 

AIR

 

1/2” (13MM) Foam Insulation

Top View

in Unconditioned Space

 

FIELD-

 

PROVIDED

EXHAUST VENT

REDUCER MAY

 

BE REQUIRED

 

TO ADAPT

INTAKE AIR

LARGER VENT

 

PIPE SIZE TO

 

TERMINATION

8” (206MM) MIN.

 

OUTSIDE WALL

DIRECT VENT WALL TERMINATION KIT

(22G44 or 44J40)

FIGURE 43

Page 31

Page 31
Image 31
Lennox International Inc Elite Series Gas Furnace, EL296UHE installation instructions Side View, Front View, Top View