Lennox International Inc EL296UHE Electrical, TABLE GAS PIPE CAPACITY - FT3/HR kL/HR

Models: EL296UHE Elite Series Gas Furnace

1 58
Download 58 pages 51.32 Kb
Page 40
Image 40
TABLE 10

TABLE 10

GAS PIPE CAPACITY - FT3/HR (kL/HR)

Nominal

Internal

 

 

 

 

Length of Pipe - feet (m)

 

 

 

Iron Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

 

 

 

 

 

 

 

 

 

 

 

Size

 

 

 

 

 

 

 

 

 

 

 

inches

10

20

30

40

 

50

60

70

80

90

100

inches

 

(mm)

(3.048)

(6.096)

(9.144)

(12.192)

 

(15.240)

(18.288)

(21.336)

(24.384)

(27.432)

(30.480)

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2

.622

172

118

95

81

 

72

65

60

56

52

50

(12.7)

(17.799)

(4.87)

(3.34)

(2.69)

(2.29)

 

(2.03)

(1.84)

(1.69)

(1.58)

(1.47)

(1.42)

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4

.824

360

247

199

170

 

151

137

126

117

110

104

(19.05)

(20.930)

(10.19)

(7.00)

(5.63)

(4.81)

 

(4.28)

(3.87)

(3.56)

(3.31)

(3.11)

(2.94)

 

 

 

 

 

 

 

 

 

 

 

 

 

1

1.049

678

466

374

320

 

284

257

237

220

207

195

(25.4)

(26.645)

(19.19)

(13.19)

(10.59)

(9.06)

 

(8.04)

(7.27)

(6.71)

(6.23)

(5.86)

(5.52)

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4

1.380

1350

957

768

657

 

583

528

486

452

424

400

(31.75)

(35.052)

(38.22)

(27.09)

(22.25)

(18.60)

 

(16.50)

(14.95)

(13.76)

(12.79)

(12.00)

(11.33)

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2

1.610

2090

1430

1150

985

 

873

791

728

677

635

600

(38.1)

(40.894)

(59.18)

(40.49)

(32.56)

(27.89)

 

(24.72)

(22.39)

(20.61)

(19.17)

(17.98)

(17.00)

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2.067

4020

2760

2220

1900

 

1680

1520

1400

1300

1220

1160

(50.8)

(52.502)

(113.83)

(78.15)

(62.86)

(53.80)

 

(47.57)

(43.04)

(39.64)

(36.81)

(34.55)

(32.844)

 

 

 

 

 

 

 

 

 

 

 

 

 

2-1/2

2.469

6400

4400

3530

3020

 

2680

2480

2230

2080

1950

1840

(63.5)

(67.713)

(181.22)

(124.59)

(99.95)

(85.51)

 

(75.88)

(70.22)

(63.14)

(58.89)

(55.22)

(52.10)

 

 

 

 

 

 

 

 

 

 

 

 

 

3

3.068

11300

7780

6250

5350

 

4740

4290

3950

3670

3450

3260

(76.2)

(77.927)

(319.98)

(220.30)

(176.98)

(151.49)

 

(134.22)

(121.47)

(111.85)

(103.92)

(97.69)

(92.31)

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE - Capacity given in cubic feet of gas per hour (kilo liters of gas per hour) and based on 0.60 specific gravity gas.

Electrical

ELECTROSTATIC DISCHARGE (ESD)

Precautions and Procedures

ElectricalCAUTION

Electrostatic discharge can affect elec­ tronic components. Take precautions to neutralize electrostatic charge by touching your hand and tools to metal prior to handling the control.

INTERIOR MAKE-UP BOX INSTALLATION

remove and relocate

plug to unused

opening on left side

MAKE-UP

BOX

Right Side

FIGURE 63

The unit is equipped with a field make-up box. The make- up box may be moved to the right side of the furnace to fa­ cilitate installation. Secure the excess wire to the existing harness to protect it from damage.

Refer to figure 64 for field wiring, schematic wiring diagram and troubleshooting.

The power supply wiring must meet Class I restrictions. Protected by either a fuse or circuit breaker, select circuit protection and wire size according to unit nameplate.

NOTE - Unit nameplate states maximum current draw. Maximum Over-Current Protection allowed is 15 AMP. Holes are on both sides of the furnace cabinet to facilitate wiring.

Install a separate (properly sized) disconnect switch near the furnace so that power can be turned off for servicing. Before connecting the thermostat check to make sure the wires will be long enough for servicing at a later date. Make sure that thermostat wire is long enough to facilitate future removal of blower for service.

Complete the wiring connections to the equipment. Use the provided unit wiring diagram and the field wiring diagram shown in figure 64. Use 18-gauge wire or larger that is suit­ able for Class II rating for thermostat connections.

Electrically ground the unit according to local codes or, in the absence of local codes, according to the current Na­ tional Electric Code (ANSI/NFPA No. 70) for the USA and current Canadian Electric Code part 1 (CSA standard C22.1) for Canada. A green ground wire is provided in the field make-up box.

NOTE - The EL296UHE furnace contains electronic components that are polarity sensitive. Make sure that the furnace is wired correctly and is properly grounded.