FIELD FABRICATED WALL TERMINATION OR
(15F74) WALL RING TERMINATION KIT
NOTE - |
|
| |
REDUCER MAY BE |
| 1/2” (13MM) ARMAFLEX | |
REQUIRED TO ADAPT |
| ||
| INSULATION IN UN | ||
LARGER VENT PIPE SIZE |
| ||
| CONDITIONED SPACE | ||
TO TERMINATION |
| ||
|
| ||
|
| SIZE TERMINATION | |
|
| PER TABLE 8 | |
|
| D | |
|
| B | |
C |
| STRAIGHT | |
A | APPPLICATION | ||
|
FIELD FABRICATED WALL TERMINATION OR
(15F74) WALL RING TERMINATION KIT
With INTAKE ELBOW
NOTE - | 1/2” (13MM) ARMAFLEX |
REDUCER MAY BE | INSULATION IN UN |
REQUIRED TO ADAPT | CONDITIONED SPACE |
LARGER VENT PIPE SIZE |
|
TO TERMINATION |
|
| SIZE TERMINATION |
| PER TABLE 8 |
| D |
| B |
| STRAIGHT |
C | APPPLICATION |
| A |
1/2” (13MM) ARMAFLEX INSULATION
IN UNCONDITIONED SPACE
| D |
* WALL | E |
| |
SUPPORT |
|
| B |
| A |
C | EXTENDED |
APPLICATION
* WALL
SUPPORT
C
1/2” (13MM) ARMAFLEX INSULATION
IN UNCONDITIONED SPACE
D
E
B
A
EXTENDED
APPLICATION
See venting table 5 for maximum venting lengths with this arrangement.
*Use wall support every 24” (610MM). Use two wall supports if extension is greater than 24” (610MM) but less than 48” (1219 MM). NOTE - One wall support must be 6” (152MM) from top of each pipe (intake and exhaust)
| 2” (51MM) | 3” (7MM) | ||
| Vent Pipe | Vent Pipe | ||
|
|
| ||
above grade or average | 12” (305MM) | 12” (305MM) | ||
snow accumulation |
|
|
| |
|
|
|
| |
|
|
| ||
separation between | 6” (152MM) | 6” (152MM) | ||
intake and exhaust |
|
|
| |
|
|
|
| |
8” (203MM) | 8” (203MM) | |||
end of exhaust to | ||||
inlet of intake |
|
|
| |
12” (305MM) | 20” (508MM) | |||
pipe length | ||||
|
|
| ||
|
|
|
| |
|
|
| ||
distance from top of each | 6” (152MM) | 6” (152MM) | ||
pipe (intake/exhaust) |
|
|
| |
|
|
|
|
FIGURE 36
See venting table 5 for maximum venting lengths with this arrangement.
*Use wall support every 24” (610MM). Use two wall supports if extension is greater than 24” (610MM) but less than 48” (1219 MM). NOTE - One wall support must be 6” (152MM) from top of each pipe (intake and exhaust)
| 2” (51MM) | 3” (76MM) | ||
| Vent Pipe | Vent Pipe |
| |
| 12” (305MM) | |||
above grade or average | 12” (305MM) | |||
snow accumulation |
|
|
| |
6” (152MM) | 6” (152MM) | |||
separation between | ||||
|
|
| ||
intake and exhaust |
|
|
| |
|
|
| ||
end of exhaust to | 6” (152MM) | 6” (152MM) | ||
inlet of intake |
|
|
| |
12” (305MM) | 20” (508MM) | |||
pipe length | ||||
|
|
| ||
|
|
|
| |
|
|
| ||
distance from top of each | 6” (152MM) | 6” (152MM) | ||
pipe (intake/exhaust) |
|
|
| |
|
|
|
|
FIGURE 37
Page 30