Goodman Mfg SSZ140181A service manual SSZ140241A, Idb

Page 9

 

 

 

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

 

COOLING OPERATION

 

MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1

 

Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Ambient Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

95

 

 

 

105

 

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet

Bulb Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

 

63

67

71

 

 

 

 

MBh

24.3

24.9

 

26.6

28.4

23.8

24.3

 

26.0

27.7

23.2

23.7

 

25.3

27.1

22.6

23.1

 

24.7

26.4

21.5

22.0

23.5

25.1

19.9

 

20.4

21.8

23.3

 

 

 

 

S/T

0.94

0.88

0.72

0.54

1.00

0.91

0.74

0.56

1.00

0.94

0.76

0.57

1.00

0.97

 

0.79

0.59

1.00

1.00

0.82

0.61

1.00

 

1.00

0.82

0.62

 

 

 

 

Delta T

22

21

18

15

23

21

19

15

22

21

19

15

22

21

 

19

15

21

21

18

15

19

 

20

17

14

 

 

 

956

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.67

1.71

1.76

1.81

1.80

1.83

1.89

1.95

1.90

1.94

2.00

2.06

2.00

2.04

 

2.10

2.17

2.08

2.12

2.19

2.26

2.15

 

2.19

2.26

2.33

 

 

 

 

AMPS

10.2

10.3

10.5

10.7

10.6

10.8

11.0

11.2

11.2

11.3

11.6

11.8

11.6

11.8

 

12.1

12.4

12.1

12.3

12.6

12.9

12.6

 

12.8

13.1

13.4

 

 

 

 

HI PR

226

244

257

268

254

273

289

301

289

311

328

343

329

354

 

374

390

370

399

421

439

409

 

440

465

485

 

 

 

 

LO PR

112

119

130

139

119

126

138

147

123

131

143

153

130

138

 

150

160

136

144

158

168

140

 

149

163

174

 

 

 

 

MBh

23.6

24.1

25.8

27.6

23.1

23.6

25.2

26.9

22.5

23.0

24.6

26.3

22.0

22.5

 

24.0

25.7

20.9

21.3

22.8

24.4

19.3

 

19.8

21.1

22.6

 

 

 

 

S/T

0.90

0.84

0.68

0.51

0.93

0.87

0.71

0.53

0.95

0.89

0.73

0.54

0.98

0.92

 

0.75

0.56

1.00

0.96

0.78

0.58

1.00

 

0.96

0.79

0.59

 

 

 

 

Delta T

23

22

19

15

23

22

19

15

23

22

19

15

23

22

 

19

16

23

22

19

15

21

 

21

18

14

 

 

80

850

KW

1.66

1.70

1.75

1.80

1.78

1.82

1.87

1.93

1.89

1.93

1.99

2.05

1.98

2.02

 

2.09

2.15

2.06

2.10

2.17

2.24

2.13

 

2.17

2.24

2.32

 

 

 

 

AMPS

10.1

10.2

10.4

10.7

10.6

10.7

10.9

11.2

11.1

11.3

11.5

11.8

11.6

11.8

 

12.0

12.3

12.0

12.2

12.5

12.8

12.5

 

12.7

13.0

13.3

 

 

 

 

HI PR

224

241

255

266

252

271

286

298

286

308

325

339

326

351

 

370

386

367

395

417

435

405

 

436

460

480

 

 

 

 

LO PR

111

118

129

138

117

125

136

145

122

130

142

151

128

136

 

149

159

134

143

156

166

139

 

148

161

172

 

 

 

 

MBh

21.8

22.3

23.8

25.5

21.3

21.8

23.3

24.9

20.8

21.3

22.7

24.3

20.3

20.7

 

22.2

23.7

19.3

19.7

21.0

22.5

17.9

 

18.2

19.5

20.8

 

 

 

 

S/T

0.86

0.81

0.66

0.49

0.90

0.84

0.68

0.51

0.92

0.86

0.70

0.52

0.95

0.89

 

0.72

0.54

0.98

0.92

0.75

0.56

0.99

 

0.93

0.76

0.57

 

 

 

 

DT

23

22

19

16

24

23

20

16

24

23

20

16

24

23

 

20

16

23

22

20

16

22

 

21

18

15

 

 

 

744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.63

1.66

1.71

1.76

1.74

1.78

1.83

1.89

1.84

1.88

1.94

2.00

1.93

1.97

 

2.04

2.10

2.01

2.05

2.12

2.19

2.08

 

2.12

2.19

2.26

 

 

 

 

AMPS

9.9

10.1

10.3

10.5

10.4

10.5

10.7

11.0

10.9

11.1

11.3

11.6

11.4

11.5

 

11.8

12.1

11.8

12.0

12.3

12.6

12.3

 

12.5

12.7

13.1

 

 

 

 

HI PR

217

234

247

258

244

263

277

289

278

299

315

329

316

340

 

359

375

356

383

404

422

393

 

423

447

466

 

 

 

 

LO PR

108

115

125

133

114

121

132

141

118

126

138

146

124

132

 

144

154

130

139

151

161

135

 

143

157

167

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

24.8

25.2

26.4

28.2

24.2

24.7

25.8

27.6

23.6

24.1

25.2

26.9

23.0

23.5

 

24.6

26.2

21.9

22.3

23.4

24.9

20.3

 

20.7

21.6

23.1

 

 

 

 

S/T

0.98

0.95

0.86

0.70

1.00

0.98

0.89

0.72

1.00

1.00

0.91

0.74

1.00

1.00

 

0.94

0.76

1.00

1.00

0.98

0.79

1.00

 

1.00

0.98

0.80

 

 

 

 

Delta T

23

23

22

19

23

23

22

19

23

23

22

19

22

23

 

22

19

21

21

22

19

19

 

20

20

18

 

 

 

956

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.69

1.72

1.77

1.83

1.81

1.85

1.90

1.96

1.92

1.96

2.02

2.08

2.01

2.05

 

2.12

2.19

2.09

2.14

2.21

2.28

2.16

 

2.21

2.28

2.35

 

 

 

 

AMPS

10.2

10.3

10.5

10.8

10.7

10.8

11.1

11.3

11.2

11.4

11.6

11.9

11.7

11.9

 

12.1

12.4

12.2

12.4

12.6

13.0

12.7

 

12.9

13.1

13.5

 

 

 

 

HI PR

229

246

260

271

257

276

292

304

292

314

332

346

332

358

 

378

394

374

402

425

443

413

 

445

470

490

 

 

 

 

LO PR

113

121

132

140

120

127

139

148

125

132

145

154

131

139

 

152

162

137

146

159

170

142

 

151

165

175

 

 

 

 

MBh

24.0

24.5

25.7

27.4

23.5

23.9

25.1

26.8

22.9

23.4

24.5

26.1

22.4

22.8

 

23.9

25.5

21.2

21.7

22.7

24.2

19.7

 

20.1

21.0

22.4

 

 

 

 

S/T

0.94

0.91

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.96

0.87

0.71

1.00

0.99

 

0.90

0.73

1.00

1.00

0.93

0.76

1.00

 

1.00

0.94

0.76

 

 

 

 

Delta T

24

24

23

20

25

24

23

20

25

24

23

20

24

25

 

23

20

23

23

23

20

21

 

22

21

18

 

 

85

850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.67

1.71

1.76

1.81

1.80

1.83

1.89

1.95

1.90

1.94

2.00

2.06

2.00

2.04

 

2.10

2.17

2.08

2.12

2.19

2.26

2.15

 

2.19

2.26

2.33

 

 

 

 

AMPS

10.2

10.3

10.5

10.7

10.6

10.8

11.0

11.2

11.2

11.3

11.6

11.8

11.6

11.8

 

12.1

12.4

12.1

12.3

12.6

12.9

12.6

 

12.8

13.1

13.4

 

 

 

 

HI PR

226

244

257

268

254

273

289

301

289

311

328

343

329

354

 

374

390

370

399

421

439

409

 

440

465

485

 

 

 

 

LO PR

112

119

130

139

119

126

138

147

123

131

143

153

130

138

 

150

160

136

144

158

168

140

 

149

163

174

 

 

 

 

MBh

22.2

22.6

23.7

25.3

21.7

22.1

23.1

24.7

21.2

21.6

22.6

24.1

20.6

21.0

 

22.0

23.5

19.6

20.0

20.9

22.3

18.2

 

18.5

19.4

20.7

 

 

 

 

S/T

0.91

0.87

0.79

0.64

0.94

0.91

0.82

0.66

0.96

0.93

0.84

0.68

0.99

0.96

 

0.87

0.70

1.00

0.99

0.90

0.73

1.00

 

1.00

0.91

0.73

 

 

 

 

Delta T

Delta T

24

23

20

25

25

23

20

25

25

23

20

25

25

 

24

20

24

25

23

20

22

 

23

22

19

 

 

 

744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.64

1.67

1.72

1.77

1.75

1.79

1.84

1.90

1.86

1.90

1.95

2.02

1.95

1.99

 

2.05

2.12

2.03

2.07

2.13

2.20

2.09

 

2.14

2.21

2.28

 

 

 

 

AMPS

10.0

10.1

10.3

10.5

10.5

10.6

10.8

11.0

11.0

11.1

11.4

11.6

11.4

11.6

 

11.9

12.1

11.9

12.1

12.3

12.6

12.3

 

12.5

12.8

13.1

 

 

 

 

HI PR

220

236

250

260

246

265

280

292

280

302

319

332

319

344

 

363

378

359

387

408

426

397

 

427

451

470

 

 

 

 

LO PR

109

116

127

135

115

122

134

142

120

127

139

148

126

134

 

146

155

132

140

153

163

136

 

145

158

168

 

9

Shaded area is ARI Rating Conditions

 

 

 

 

IDB: Entering Indoor Dry Bulb Temperature

 

KW=Total system power

 

 

 

 

AMPS=outdoor unit amps (comp.+fan)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLING PERFORMANCE DATA

SSZ140241A*

Image 9
Contents Technical Information Manual Product Identification 036Product Identification Product Design AA AALight Commercial SSZ140181A* SSZ140601A Heat Pump SpecificationsSSZ140181A Cooling Performance DataCooling Operation SSZ140181ASSZ140241A IDB SSZ140241ASSZ140301A 28.8 SSZ140301A368 151SSZ140361A 34.28 SSZ140361ASSZ140421A 13.4 13.8 14.3 SSZ140481A SSZ140481A SSZ140601A 56.0 SSZ140601A18,000 13,203 797 483 Performance DataExpanded Performance Data Split System Heating Performance41.0 Outdoor Ambient TemperatureHeating Specifications Capacity Btuh19.2 51.54 Performance Test Wiring is subject to change Wiring