XDT User’s Manual Appendices

Appendix A: Flow Diagram of Operating State User Interface

Power ON initialization

30 seconds anywhere (other than

appears when changing

and sign on message

"Calibration") without key press

settings of locked unit

 

 

 

HI/LO

˚C

 

 

 

 

and/orHIFlashingLO

correspondingindicates

energizednotrelays

DEWPOINT PSI

 

{

 

 

 

 

units

 

 

 

 

SET

 

 

 

 

HI

 

 

1)

 

{

 

 

(Relay

 

 

 

 

 

choices

 

 

HIAlarm

 

SET

 

 

 

{

 

 

 

 

HI

˚C

 

 

 

DEWPOINT

 

installed

Setting

 

values

 

 

 

 

 

 

 

 

SET

 

 

 

 

HI

˚C

options are

 

 

 

 

 

{

 

alarm

 

 

values

 

 

 

SET

 

if

 

 

LO

 

(Relay2)

 

 

 

Displayedonly

 

{

 

 

LOAlarm

 

choices

 

 

 

{

 

 

 

 

SET

 

 

 

 

LO

˚C

 

 

 

DEWPOINT

 

 

Setting

 

values

 

 

 

 

 

 

 

 

SET

 

 

 

 

LO

˚C

 

 

 

 

 

 

 

{

 

values

Toggle Pressure Correction

Viewing Dewpoint

Flashing PSI indicates pressure corrected dewpoint

SHORT PRESS

LONG PRESS

AND PSI MODE

Set activity options

Set trigger dewpoint

Set hysteresis

Set activity options

Set trigger dewpoint

Set hysteresis

1/2 sec

 

Toggle 14.7 psi

SET

 

VALUE

View/Set

PSI

Sensor

 

{

Pressure

SHORT PRESS

values

 

 

LONG PRESS

SET

Toggle 14.7 psi

 

VALUE

View/Set

PSI

Gas

 

{

Pressure

SHORT PRESS

values

LONG PRESS

 

Relay polarity:

= energize relay above trigger dewpoint

= energize relay below trigger dewpoint appropriate polarity selection in conjunction with proper wiring wll provide fail safe operation

Scroll through Alarm activity options

Fault reaction:

= faults do Not effect relays

= faults "look" like High dewpoint

= faults "look" like Low dewpoint = faults Flash the relay

Cancel Calibration (it is not performed)

When a third Alarm Relay is installed,

 

 

 

 

 

 

 

setup menu options will appear here

 

 

 

 

 

 

 

similar to Relays 1&2, but with both

 

 

 

 

 

 

 

the HI&LO legends active. This is

 

 

 

 

 

 

 

also the dewpoint alarm for units with

 

 

 

 

 

 

 

resetable Audio-Visual Alarm.

 

 

 

 

 

 

 

SET

few sec

SET

NUMBERS

 

Sensor

SET

 

Start

 

CALCULATING

 

 

 

Calibration

 

CALIBRATION

OK

Reading

 

 

 

 

 

 

see Self-Cal user

 

 

 

TOO LOW

Confirm

{

 

 

 

 

 

 

 

 

 

 

 

SpanCheck

interface next page

 

 

 

 

 

 

 

 

 

 

again

 

 

 

 

 

 

 

 

Confirm SpanCheck

 

 

 

 

 

 

 

Viewing

 

SET

1 sec

 

SET

SET

 

Serial-

go to

 

 

 

 

 

 

 

 

 

 

 

number

Set-Up

 

 

 

 

1 minute

{

 

State

 

 

 

 

 

 

 

 

 

 

 

Press together

 

New calibration

 

ignore error

 

to RESET the

 

values are saved

 

 

 

 

 

 

 

 

 

instrument

 

 

 

 

 

 

Legend: A slash '' in the display area, is used to depict two alternately shown (flashing back and forth) messages. denotes beeping. Buttons without designator or arrow leading out, perform no function

37

Page 44
Image 44
Epson XDT manual Appendix a Flow Diagram of Operating State User Interface, Sign on message Calibration without key press