Bard PA13481-A, PA13421-A, PA13481-B, PA13601-A, PA13421-B Unit Dimension Chart, Dimensions of Units

Page 8

FIGURE 1

DIMENSIONS OF UNITS

W

L

D

Compressor access door

Control panel door

High voltage knockout

Low voltage knockout

Heater package knockout

Heater package access panel

Drain access

F

H

Blower motor

 

access door

47 11/16"

G

Condenser air intake grille

A

E

B

Supply opening

C

Return opening

Condenser fan

Condenser air intake grille

Unit Dimension Chart

 

Unit

Supply Size

Return Size

Unit Overall Dimensions

 

Unit General Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

C

B

C

H (height)

L (length)

W (width)

D

 

E

F

 

G

 

 

 

 

PA/PH1324,1330,1336

5.875

32.875

13.875

32.875

26.25

53.25

38.125

23.25

 

1.125

1.375

 

35.625

PA/PH1342,1348,1360

9.875

37.875

15.875

37.875

33.25

55.25

42.375

30.25

 

1.5

2.375

 

38.125

 

 

 

 

 

 

 

 

 

 

 

 

 

MIS-2142

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual

2100-467

 

 

 

 

 

 

 

 

 

 

 

 

 

Page

8 of 23

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 8
Contents Bard Manufacturing Company Bryan, OhioContents Getting Other Information and Publications For More INFORMATION, Contact These PublishersField Installed Heater Packages Optional General InstructionsShipping Damage GeneralElectrical Specifications Hz Circuit aHeater Package Volts Model Phase Optional Field Installed Electric Heater Table Htr. KW & Capacity Circuit BUnit Dimension Chart Dimensions of UnitsInstallation Typical InstallationsLocation GeneralAirflow and Service Access Clearances Slab Mounting AT Ground LevelElevated Mounting Platform AS RequiredCondensate Drain Trap AIR FiltersFilter Requirements & Sizes Condensate Drain TrapWiring Main Power Wiring 24V LOW Voltage Control CircuitTransformer Taps ThermostatsLOW Voltage Wiring Unit Control PanelSafety Practices Start UPTopping OFF System Charge Start UP NotesThree Phase Scroll Compressor Start UP Information Start UP and OperationSequence of Operation Indoor Blower MotorAdjustments Alarm OutputAdjustable DELAY-ON-MAKE and DELAY-ON-BREAK Timer LOW Ambient Control WiringService and Troubleshooting Service HintsPressure Service Ports FAN Blade SettingsBrazing Diagram Suction and Discharge Tube BrazingTroubleshooting GE ECM Motors Troubleshooting GE ECM Motors Cont’d Pressure Table On Page 23 in TableReturn Air Pressure 100 105 115 120 125 ModelReturn Air Pressure 100 105 110 115 120 125 Model

PA13601-B, PA13481-A, PA13601-A, PA13481-B, PA13421-A specifications

Bard is a renowned name in the HVAC (Heating, Ventilation, and Air Conditioning) industry, known for its innovative products that ensure comfort and efficiency in various settings. The models PA13421-B, PA13421-A, PA13481-B, PA13601-A, and PA13481-A are prime examples of Bard's commitment to quality and technology, providing reliable performance and advanced features suitable for both commercial and residential applications.

The PA13421-B and PA13421-A are designed for energy efficiency, boasting high SEER (Seasonal Energy Efficiency Ratio) ratings that significantly reduce energy consumption without sacrificing performance. These units utilize a scroll compressor, which is known for its quiet operation and superior reliability. Additionally, they feature advanced microprocessor control systems that allow for precise temperature regulation and can be easily integrated into building management systems.

The PA13481-B and PA13481-A models are equipped with durable, heavy-gauge cabinets that protect the internal components from environmental factors, ensuring longevity and minimal maintenance. These units also incorporate a high-capacity airflow design, which improves indoor air quality by effectively circulating air throughout the space. The implementation of variable-speed blowers further enhances comfort levels by adjusting airflow based on real-time demand.

The PA13601-A model stands out with its versatility, as it can operate effectively in a wide range of climates. Its design includes a robust refrigerant management system that ensures optimal performance even in extreme temperatures, making it a favorite for users in harsher environments. This model also features a comprehensive diagnostic system that alerts users to potential issues before they escalate, facilitating proactive maintenance.

All these models emphasize sustainability, incorporating environmentally friendly refrigerants that comply with international regulations. Bard's dedication to reducing carbon footprints is evident in these units, which not only perform admirably but also contribute to a greener planet.

In summary, the Bard PA13421-B, PA13421-A, PA13481-B, PA13601-A, and PA13481-A models exemplify cutting-edge technology and superior engineering in the HVAC sector. With their energy-efficient designs, robust construction, and advanced control systems, these HVAC solutions provide reliable comfort for users while being mindful of environmental impact.