PA13-SERIES PACKAGED AIR CONDITIONERS

Cooling Capacities: 23,000 to 56,000

SEER: 13.0

GREEN REFRIGERANT R-410A

BACK (OUTDOOR AIRFLOW) END OF UNIT

Standard Engineered Features

FRONT (INDOOR AIRFLOW) END OF UNIT

Field Installed Accessories

Air Conditioner Compressor: Reciprocating compressors with crankcase heaters are standard on 2, 2½ and 3-ton models. Scroll compressors are used on all other models and no crankcase heaters are required.

R-410A Refrigerant:

Designed with R-410A (HFC) non- ozone depleting refrigerant in compliance with the Montreal protocol and 2010 EPA requirements.

ECM Indoor Blower Motor: Features an electronically commutated motor providing super-high efficiency, low sound levels and soft-start capabilities. The motor is self- adjusting to provide the proper airflow rate for a broad range of static pressure in ducted installations without user adjustment or wiring changes.

Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency.

Outdoor coil is constructed with special corrosion resistant hydrophilic fin stock with 2-layer coating. (1st layer - blue acrylic primer; 2nd layer - clear topcoat.)

Thermal Expansion Valves: Models with reciprocating compressors have bleed TXV, models with scroll compressor have non-bleed TXV.

Discharge Muffler:

Standard on 2½ and 3-ton models.

Liquid Line Filter Drier: Protects system against moisture.

Compressor Control Module: Built-in off-delay timer adjustable from 30 seconds to 5 minutes. 2-minute on-delay if power interrupt. 120- second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay.

Phase Rotation Monitor: Standard on all 3-phase models. Protects against reverse rotation if power supply is not properly connected.

High & Low Pressure Switches are Auto-Reset

Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor.

Pre-Painted 20 Gauge Zinc Coated Steel Cabinet:

Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03.

Pre-Painted 16 Gauge Zinc Coated Unit Base:

The unit base is treated with the same paint coatings as the cabinet above, insuring years of service.

Top Discharge Outdoor Fan: Efficiently moves air quietly for effective heat exchange.

Electrical Components & Controls: Readily accessible for easier service.

Optional Field Installed Electric Heat

Strips:

With automatic limit and thermal cutoff.

Field installed heater package for all models.

Features slide-in field assembly with various BTUH outputs.

Permits stocking of only one unit.

Optional Field Installed Low Ambient

Control:

Cycles outdoor fan motor below 55°F outdoor temperature to maintain acceptable condensing pressure.

Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Third Edition.

Form No.

S3383-1112

Supersedes

S3383-510

Page

1 of 8

Image 1
Contents Field Installed Accessories Standard Engineered FeaturesCooling Capacities and Efficiency Ratings General SpecificationsIndoor Blower Performance Optional Field Installed Electric Heater through 5 Ton Optional Field Installed Electric Heater PackagesCooling Application Data Outdoor Temperature Top Optional Control Modules Field Installed Unit DimensionsField Installed Part Applicable To Description Model No Applicable To Optional Equipment Roof HoodVentilation Rate Optional Equipment Energy Recovery VentilatorWHR WHR WVL