Friedrich H)A12K34L, R410A, H)A12K25L, H)A09K34L, H)A24K25L, H)A12K50L Refrigeration System Hazards

Page 5

Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning.

Electrical component malfunction caused by water could result in electric shock or other electrically unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry.

Never operate the A/C unit with wet hands.

Use air conditioner on a single dedicated circuit within the specified amperage rating.

Use on a properly grounded outlet only.

Do not remove ground prong of plug.

Do not cut or modify the power supply cord.

Do not use extension cords with the unit.

Follow all safety precautions and use proper and adequate protective safety aids such as: gloves, goggles, clothing, adequately insulated tools, and testing equipment etc.

Failure to follow proper safety procedures and/or these warnings can result in serious injury or death.

REFRIGERATION SYSTEM HAZARDS:

Use approved standard refrigerant recovering procedures and equipment to relieve pressure before opening system for repair.

Do not allow liquid refrigerant to contact skin. Direct contact with liquid refrigerant can result in minor to moderate injury.

Be extremely careful when using an oxy-acetylene torch. Direct contact with the torch’s flame or hot surfaces can cause serious burns.

Make sure to protect personal and surrounding property with fire proof materials.

Have a fire extinguisher at hand while using a torch.

Provide adequate ventilation to vent off toxic fumes, and work with a qualified assistant whenever possible.

Always use a pressure regulator when using dry nitrogen to test the sealed refrigeration system for leaks, flushing etc.

Make sure to follow all safety precautions and to use proper protective safety aids such as: gloves, safety glasses, clothing etc.

Failure to follow proper safety procedures and/or these warnings can result in serious injury or death.

MECHANICAL HAZARDS:

Extreme care, proper judgment and all safety procedures must be followed when testing, troubleshooting, handling, or working around unit with moving and/or rotating parts.

Be careful when, handling and working around exposed edges and corners of sleeve, chassis, and other unit components especially the sharp fins of the indoor and outdoor coils.

Use proper and adequate protective aids such as: gloves, clothing, safety glasses etc.

Failure to follow proper safety procedures and/or these warnings can result in serious injury or death.

3

Image 5
Contents R v i c e M a n u a l R 4 1 0 a M o d e l s Introduction Technical Support Contact InformationTable of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards Production RUN Number Product Line Serial Number Year ManufacturedMonth Manufactured Model Chassis SpecificationsIndoor WET Bulb TEMP. Degrees F AT 80 F D.B Extended Cooling PerformanceElectric Shock Hazard Electrical RequirementsRT5 Two speed fan RT4 One speed fan Remote Thermostat and Low Voltage Control ConnectionsThermostat Connections Quiet Start/Stop Electronic Control Board FeaturesElectronic Control Configuration Test Mode Electronic Control Error Code DiagnosticsDiagnostics Thermostat Compatibility Vpak electronic control FeaturesExternal Static Pressure Explanation of charts Capacitors Components TestingCapacitor Check with Capacitor Analyzer Capacitor ConnectionsDrain PAN Valve Components TestingHeater Elements and Limit SWITCHES’ Specifications Refrigeration Sequence of Operation Refrigeration AssemblyCUT/SEVER Hazard ServiceEquipment Required Sealed Refrigeration System RepairsEquipment Must be Capable Risk of Electric ShockUndercharged Refrigerant Systems Method Of Charging / RepairsBurn Hazard Freeze HazardRestricted Refrigerant System Overcharged Refrigerant SystemsMetering Device Hermetic Components CheckCheck Valve Capillary Tube SystemsChecking the Reversing Valve Testing the CoilReversing Valve DESCRIPTION/OPERATION Fire Hazard Procedure For Changing Reversing ValveTouch Test in Heating/Cooling Cycle Compressor Checks External Overload Vpak 9, 12, 18 K Btus Single Phase Resistance TestInternal Overload Vpak 24 K Btus Ground TestHigh Temperatures Compressor ReplacementRecommended procedure for compressor replacement Electrical Shock Hazard Routine Maintenance9K BTU, 12K BTU, & 18K BTU Electrical Troubleshooting Chart CoolingCircuit Breakers are Electrical Troubleshooting Chart Cooling 24K BTUHeat Pump Mode Electrical Troubleshooting Chart Heat PumpTroubleshooting Chart Heating Troubleshooting Chart CoolingElectric Heat VEA 09/12/18 with 2.5 KW, 3.4 KW or 5KWVHA 09/12/18 with 2.5 KW, 3.4 KW or 5KW Cool with Electric Heat Heat Pump with Electric Heat Cool with Electric Heat Heat Pump with Electric Heat Technical Service Data Technical Service DataVPK-ServMan-L Friedrich AIR Conditioning CO
Related manuals
Manual 7 pages 15.54 Kb Manual 61 pages 11.89 Kb Manual 27 pages 24.75 Kb

H)A09K25L, H)A12K50L, H)A09K50L, H)A24K10L, H)A24K25L specifications

Friedrich R410A is a refrigerant blend that has become a cornerstone in the HVAC industry, particularly for air conditioning systems. This hydrofluorocarbon (HFC) is known for its efficiency and environmentally friendly properties, making it a popular alternative to older refrigerants like R22.

One of the main features of R410A is its exceptional thermal efficiency. It has a higher cooling capacity compared to R22, which allows for smaller and more efficient equipment. This efficiency translates to reduced energy consumption and lower operating costs for users. Additionally, the higher pressure capability of R410A enables the design of more compact systems, which is particularly beneficial for residential and commercial applications where space is often limited.

R410A is characterized by its zero ozone depletion potential (ODP), which is a significant advantage over its predecessors. This makes it a more environmentally responsible choice, aligning with global initiatives to phase out substances that harm the ozone layer. However, it is essential to note that while R410A does not deplete the ozone, it does have a global warming potential (GWP) of approximately 2,088, making it less favorable in terms of climate impact compared to natural refrigerants.

In terms of technology, R410A is typically utilized in systems that are designed specifically for this refrigerant. Equipment compatible with R410A often features advanced components that can handle the higher pressures required. Many modern air conditioning systems equipped with R410A also incorporate variable-speed compressors and advanced electronic controls, enhancing overall performance and comfort.

Additionally, R410A systems often come equipped with variable refrigerant flow (VRF) technology, which allows for precise temperature control in multiple zones of a building. This versatility makes R410A an ideal choice for both residential and commercial installations, providing optimal comfort throughout various spaces.

In summary, Friedrich R410A stands out due to its high energy efficiency, zero ozone depletion potential, and suitability for modern HVAC technologies. As the industry moves towards more sustainable practices, R410A serves as a reliable refrigerant that balances performance with environmental responsibility. It’s a significant choice for anyone looking to invest in efficient and eco-friendly heating and cooling solutions.