P 16/16
Wiring diagram
Fig. D-4
HS6101 & HS7101
(with Electric brake and LED light)
Be careful not to put Lead wire (blue or white) of Power supply cord on Noise suppressor after connecting
it to Terminal block.
Route Field lead wires and | Fix Lead wires of |
Lead wires of LED Light circuit | LED Light circuit |
into Handle section through | in this Lead wire |
this groove. | holder. |
Switch |
|
Field lead wires must be tight in Motor housing.
Fix Lead wires of LED Light circuit in these Lead wire holders.
Be careful not to put |
|
| Field |
Lead wires on the boss |
|
| |
and ribs A, B, C, D. |
|
|
|
|
| rib C rib D | LED Light |
|
| circuit | |
Strain relief |
|
|
|
rib A |
|
|
|
Noise suppressor | rib B |
| |
(if used) |
| boss | Fix Field lead wires |
|
| in these Lead wire | |
|
| Terminal block | holders. |
If Noise suppressor is used, |
| Set Terminal block in Handle section | Field lead wires must be |
route Noise suppressor’s lead |
| with each terminal positioned as follows: | tight in Motor housing. |
wires between rib A and rib B. | *On Strain relief side, the terminal with which |
| |
Be careful not to put them on |
| the Lead wire of Power supply cord is connected |
|
Noise suppressor, ribs A and B. |
| must be positioned. |
|
*On Field side, the terminal with which the Field lead wire is connected must be positioned.