TROUBLESHOOTING AND REPAIR | ||
| KEYPAD RESISTANCE TEST (continued) |
|
| NOTE: There should not be continuity |
|
| between pins until a key is pressed on the |
|
| keypad. |
|
TABLE F.1 — KEYPAD RESISTANCE TEST.
|
|
|
| MAXIMUM |
TEST POINTS |
| ALLOWABLE RESISTANCE | ||
FROM PIN | TO PIN |
| KEY PRESSED | (TYPICAL RESISTANCE) |
1J10 | 2J10 | CONTROL | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 3J10 | TIMER | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 4J10 | TRIGGER | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 6J10 | PROCEDURE | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 7J10 | COLD FEED FORWARD | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 8J10 | COLD FEED REVERSE | 100 OHMS (50 OHMS TYPICAL) | |
1J10 | 9J10 | GAS PURGE | 100 OHMS (50 OHMS TYPICAL) | |
|
|
|
|
|