Section TOC
Master TOC
TROUBLESHOOTING AND REPAIR | ||
|
|
|
OUTPUT CAPACITORS REPLACEMENT (Continued)
PROCEDURE
Return to
TOC
Return to
TOC
1.Using a 3/8” nutdriver, remove the lower right side case wraparound cover. See Figure F.14.
2.Locate capacitor bank. See Figure F.14.
3.Label and remove the five leads connected to the capacitor bank using a 1/2” wrench. Note washer position upon removal. See Figure
F.15.
4.Using a 3/8” nutdriver, remove the three capac- itor bank nuts and lock washers from the three mounting bolts. See Figure F.15.
5.Remove the capacitor bank assembly from the machine.
6.Place the new capacitor bank into its proper location inside the machine.
7.Replace the three 3/8” nuts and lock washers previously removed.
8.Using a 1/2” wrench, reconnect the five labeled leads and associated washers previously removed.
9.Replace the lower right side case wraparound cover previously removed.
Return to Section
Return to Section TOC
Return to Section TOC
Return to Master
Return to Master TOC
Return to Master TOC
FIGURE F.14. - CAPACITOR BANK LOCATION
LOWER RIGHT
CASE WRAPAROUND
COVER
CAPACITOR BANK
ASSEMBLY