Lincoln Electric SVM167-A service manual Volts 20.0

Page 62

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-26

TROUBLESHOOTING AND REPAIR

F-26

ABNORMAL OPEN CIRCUIT VOLTAGE

OUTPUT CAPACITOR BANK NOT FUNCTIONING (MAX TAP “G”)

0 Volts

20.0 V

5 ms

SCOPE SETTINGS

This is NOT a typical DC output voltage

 

 

waveform. The output

capacitors

are

Volts/Div

20V/Div

not functioning. Note the lack of “filter-

 

 

ing” in the output waveform. The output

Horizontal Sweep

5 ms/Div

capacitor bank was disconnected. Each

 

 

vertical division represents 20 volts and

Coupling

DC

each horizontal division represents 5

 

 

milliseconds in time.

 

 

Trigger

Internal

NOTE: Scope probes

connected

at

 

 

machine output

terminals: (+)

 

 

probe to electrode, (-) probe to

 

 

work.

 

 

 

 

 

 

 

 

 

POWER MIG® 215

Image 62
Contents Power MIG Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burn Can be dangerousIii Welding and Cutting Sparks can cause fire or explosionCylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation SECTION Installation Technical Specifications Power MIGInstallation Safety PrecautionsUncrating the Power MIG LocationOutput Polarity Connections Shielding GAS GUN and Cable InstallationAUXILIARY POWER RECEPTACLES Cylinder may explode if damagedPower MIG Operation SECTION  OPERATIONB-2 Wear eye, ear and body protec- tionOperation To Start the Welder Procedure for Changing Drive AND IDLE Roll SetsWire Reel Loading READI-REELS, Spools or Coils Wire Drive Configuration Feeding Wire ElectrodeIdle Roll Pressure Setting Making a Weld Figure B.2bFAN Control Avoiding Wire Feeding ProblemsWire Feed Overload Protection Input Line Voltage VariationsPower MIG Accessories SECTION  Accessories Making a Weld with the Spool GUN 3ACCESSORIESC-3Installed Adapter KIT and Spool GUNPower MIG Maintenance SECTION  Maintenance Liner Removal and Replace Ment Table D.1GUN Handle Disassembly English Metric Description SizeFigure D.2 Major Component Locations Power MIG Line Switch Theory of Operation SECTION Figure E.2 Input Power Circuit Theory of OperationOutput Rectification Contactor and Control Board Figure E.3 Control CircuitsControl BOARD, GUN Trigger and Wire Drive Motor Figure E.4 Optional CircuitsThermal and Overload Protection Wirefeed Overload ProtectionProtective Devices and Circuits Power MIG TROUBLESHOOTING AND REPAIR SECTION  Troubleshooting and Repair How To Use Troubleshooting GuidePC Board Troubleshooting Procedures Perform the Main Transformer Perform the Output Contactor Your body These capacitors is toxicAvoid contact with any portion Function Problems Wire Speed Potentiometer Test Welding Problems Weld bead is narrow or ropy Make sure the welding proce Materials Needed Main Transformer TestTest Description Main Transformer Test Test ProcedureON/OFF Power Switch will be hot during these tests X10 Table F.1. Test Points Input Voltage Test PointsWire Drive Motor and Wire Speed Potentiometer Test Black WhiteVDC Test for Feedback Voltage to Control Board1109 a Power MIG Output Bridge Rectifier Test Negative Lead Output Bridge Rectifier TestContactor Test Contactor Test Figure F.7. Contactor Terminals and LeadsVolts 10.0 Typical Output Voltage Waveform Machine Loaded MAX TAP GVolts 20.0 Normal Open Circuit Voltage Waveform MAX TAP GMachine Loaded to 180 Amps AT 16 VDC Scope Settings Volts 20.0 Control Board Replacement DescriptionControl Board Replacement ProcedureWire Drive Motor Assembly Replacement Wire Drive Wire Drive Motor Assembly ReplacementBolt Gas Hose TOC Output Diode Bridge Rectifier Replacement Output Diode Bridge Rectifier Mounting Bracket Mounting Bolts Rectifier Power MIG Output Capacitors Replacement Output Capacitors Replacement Figure F.14. Capacitor Bank LocationLead Mounting Bolts Nuts Lock washers 3 places Power MIG 41TROUBLESHOOTING and Repair F-41 Main Transformer ReplacementMain Transformer Replacement See Figure F.17Replacement Figure F.17. Leads X9, X10, 104B,104C, & H1BX2 X3 X4 X5 X6 X7 Lead Power MIG FAN BLADE/MOTOR Replacement FAN BLADE/MOTOR Replacement Perform the Output Capacitor Bank Removal ProcedureOutput Contactor Replacement Output Contactor Replacement Figure F.24Mounting Bolts Retest After Repair Electrical Diagrams Table of Contents Electrical Diagrams SectionPower MIG 215 208/220/230V POWEr miGPower MIG 215 208/220/230V for Codes 11099 SchEmaTic cOmplETE machiNE cODE 11247 l12308 pG1 L12308SchEmaTic cOmplETE machiNE cODE 11247 l12308 pG2 ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS