Lincoln Electric SVM167-A service manual Main Transformer Replacement, See Figure F.17

Page 78

TOC

F-42

TROUBLESHOOTING AND REPAIR

F-42

 

 

 

MAIN TRANSFORMER REPLACEMENT (Continued)

PROCEDURE

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

1.Using a 3/8” nutdriver, remove both sides of the case wraparound cover.

2.Using a 5/16” nutdriver, remove the tool tray.

3.Locate the main transformer. See Figure F.16.

4.Label and disconnect leads X9, X10, 104B, & 104C. See Figure F.17.

5.Using a flathead screwdriver, Label and dis- connect lead H1B and other associated lead connected to the same terminal. These leads are connected to the ON/OFF switch.

See Figure F.17.

6.Using a 7/16” nutdriver, Label and discon- nect leads X8, X7, X6, X5, X4, X3, & X2 from the switch assembly. Note washer position upon removal. See Figure F.18.

7.Using a 1/2” nutdriver, label and remove lead X1 from the output diode bridge rectifi- er.

8.Using a 5/16” Nutdriver, open the rear access panel. See Figure F.20.

9.Disconnect lead 118 from the rear access panel. See Figure F.21.

10.Feed lead 118 toward the inside of the machine.

11.Cut any necessary cable ties.

12.Remove any necessary wiring harnesses.

13.Disconnect lead 121. See Figure F.19.

14.Using a 1/2” nutdriver, remove the four main transformer mounting bolts and associated washers. See Figure F.16.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE F.16. - MAIN TRANSFORMER LOCATION

Main Transformer

1/2" Mounting

Bolts

POWER MIG® 215

Image 78
Contents Power MIG Safety Depends on YouSafety California Proposition 65 WarningsElectric Shock can kill ARC Rays can burn Can be dangerousWelding and Cutting Sparks can cause fire or explosion Cylinder may explode if damagedIii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation SECTION Installation Technical Specifications Power MIGInstallation Safety PrecautionsUncrating the Power MIG LocationOutput Polarity Connections Shielding GAS GUN and Cable InstallationAUXILIARY POWER RECEPTACLES Cylinder may explode if damagedPower MIG Operation SECTION  OPERATIONB-2 Wear eye, ear and body protec- tionOperation Procedure for Changing Drive AND IDLE Roll Sets Wire Reel Loading READI-REELS, Spools or CoilsTo Start the Welder Feeding Wire Electrode Idle Roll Pressure SettingWire Drive Configuration Making a Weld Figure B.2bFAN Control Avoiding Wire Feeding ProblemsWire Feed Overload Protection Input Line Voltage VariationsPower MIG Accessories SECTION  Accessories Making a Weld with the Spool GUN 3ACCESSORIESC-3Installed Adapter KIT and Spool GUNPower MIG Maintenance SECTION  Maintenance Liner Removal and Replace Ment Table D.1GUN Handle Disassembly English Metric Description SizeFigure D.2 Major Component Locations Power MIG Line Switch Theory of Operation SECTION Figure E.2 Input Power Circuit Theory of OperationOutput Rectification Contactor and Control Board Figure E.3 Control CircuitsControl BOARD, GUN Trigger and Wire Drive Motor Figure E.4 Optional CircuitsWirefeed Overload Protection Protective Devices and CircuitsThermal and Overload Protection Power MIG TROUBLESHOOTING AND REPAIR SECTION  Troubleshooting and Repair How To Use Troubleshooting GuidePC Board Troubleshooting Procedures Perform the Main Transformer Perform the Output Contactor These capacitors is toxic Avoid contact with any portionYour body Function Problems Wire Speed Potentiometer Test Welding Problems Weld bead is narrow or ropy Make sure the welding proce Main Transformer Test Test DescriptionMaterials Needed Test Procedure ON/OFF Power Switch will be hot during these testsMain Transformer Test X10 Table F.1. Test Points Input Voltage Test PointsWire Drive Motor and Wire Speed Potentiometer Test Black WhiteTest for Feedback Voltage to Control Board 1109 aVDC Power MIG Output Bridge Rectifier Test Negative Lead Output Bridge Rectifier TestContactor Test Contactor Test Figure F.7. Contactor Terminals and LeadsVolts 10.0 Typical Output Voltage Waveform Machine Loaded MAX TAP GVolts 20.0 Normal Open Circuit Voltage Waveform MAX TAP GMachine Loaded to 180 Amps AT 16 VDC Scope Settings Volts 20.0 Control Board Replacement DescriptionControl Board Replacement ProcedureWire Drive Motor Assembly Replacement Wire Drive Wire Drive Motor Assembly ReplacementBolt Gas Hose TOC Output Diode Bridge Rectifier Replacement Output Diode Bridge Rectifier Mounting Bracket Mounting Bolts Rectifier Power MIG Output Capacitors Replacement Output Capacitors Replacement Figure F.14. Capacitor Bank LocationLead Mounting Bolts Nuts Lock washers 3 places Power MIG 41TROUBLESHOOTING and Repair F-41 Main Transformer ReplacementMain Transformer Replacement See Figure F.17Replacement Figure F.17. Leads X9, X10, 104B,104C, & H1BX2 X3 X4 X5 X6 X7 Lead Power MIG FAN BLADE/MOTOR Replacement FAN BLADE/MOTOR Replacement Perform the Output Capacitor Bank Removal ProcedureOutput Contactor Replacement Output Contactor Replacement Figure F.24Mounting Bolts Retest After Repair Electrical Diagrams Table of Contents Electrical Diagrams SectionPower MIG 215 208/220/230V POWEr miGPower MIG 215 208/220/230V for Codes 11099 SchEmaTic cOmplETE machiNE cODE 11247 l12308 pG1 L12308SchEmaTic cOmplETE machiNE cODE 11247 l12308 pG2 ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS ElEcTrical DiaGramS