OPERATIONB-9

the one that did not match (see Memory Number Key Section).

4-STEP TRIGGER INTERLOCK KEYS

Pressingand

Controls whether 4-step trigger interlock is activated or deactivated. (See “Using 4-Step Trigger Interlock Function” section.)

NOTE: 4-Step Trigger is automatically deactivated if either the spot or stitch timer mode is being used.

TYPICAL ACTIVATE KEY PRESS SEQUENCE

Auto screen is displayed prior to pressing keys. Process key is pressed and held, then Toggle key is pressed. The auto screen now displays the 4T symbol in the upper left corner indicating that the 4-step trig- ger interlock is now active.

TYPICAL DEACTIVE KEY PRESS SEQUENCE

Auto screen is displayed prior to pressing keys. Process key is pressed and held, then Toggle key is pressed. The 4T symbol is no longer displayed in the upper left corner indicating that the 4-step trigger interlock no longer functions.

USING 4-STEP TRIGGER INTERLOCK FUNCTION

When the function is deactivated, the trigger will func- tion in the normal mode which welds only when the trigger is closed.

When activated, the trigger will function as follows:

Once the arc has been struck, the gun trigger may be released and the welding will continue until welding is stopped by either of two methods:

1.The arc is extinguished by manually jerking the gun away from the work.

2.The gun trigger is depressed before the end of the weld returning the trigger function to normal mode so the weld will be stopped when the trig- ger is released. Releasing the trigger reinstates the trigger interlock function for the next weld.

The second trigger interlock stopping method per- mits the user better control at the finish of the weld and allows automatic burnback to prevent exces- sive wire feed speed overrun.

The 4-step trigger feature does not function when using SPOT or STITCH timed welding modes. (See “Spot and Stitch Weld Modes” in this section.)

IDEALARC SP-255

Image 21
Contents Idealarc SP-255 Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Master Table of Contents for ALL Sections Section E Section DSection F AppendixTechnical Specifications Idealarc SP-255 INSTALLATIONA-1Safety Precautions 2INSTALLATIONInput Power and Grounding Connections Uncrating the SP-255INSTALLATIONA-3 GUN and Cable InstallationOutput Polarity Connection Shielding GAS 4INSTALLATIONFumes and Gases can be dangerous OPERATIONB-1Recommended Processes and Equipment 2OPERATIONWelding Capability LimitationsStart Mode Selections Process WIRE/GAS KEYOPERATIONB-3 4OPERATION Procedure KeysAuto KEY Typical Auto KEY Press SequencesMemory Keys OPERATIONB-5 6OPERATION Timer Keys Typical Memory Number KEY Press Sequence Spot KEYOPERATIONB-7 GUN Switch KeysTypical Toggle KEY Press Sequence 8OPERATIONOPERATIONB-9 Using 4-STEP Trigger Interlock FunctionStep Trigger Interlock Keys Typical Activate KEY Press SequenceWire Drive Roll GUN SwitchesProcedure for Changing Drive Roll Wire Reel LoadingOPERATIONB-11 Idle Roll Pressure SettingTo Start the Welder Feeding Electrode12OPERATION Making AN Auto Mode WeldOPERATIONB-13 Explanation of Prompting and Error Messages Wire Feed Overload Protection14OPERATION Welding Thermal Overload ProtectionOPERATIONB-15 Operation ACCESSORIESC-1 2ACCESSORIES Disabling Spool GUN ACCESSORIESC-3Idealarc SP-255 Safety Precautions MAINTENANCED-1Cable Cleaning Routine MaintenanceLiner Removal Replacement 2MAINTENANCEMAINTENANCED-3 GUN Handle DisassemblyMagnum 250SP GUN Parts and Accessories Idealarc SP-255 HOW to USE Troubleshooting Guide TROUBLESHOOTINGE-1Troubleshooting Guide 2TROUBLESHOOTINGProblems Possible Areas Symptoms Misadjustments Authorized Field Service FacilityTROUBLESHOOTINGE-3 4TROUBLESHOOTING Authorized Field Service FacilityContact your local Lincoln Function Problems TROUBLESHOOTINGE-5Contact your local Lincoln Authorized Field Service Facility 6TROUBLESHOOTINGSP-255 Wiring Diagram L9688 Dual Voltage Wiring DiagramsWiring Diagrams Dimension Print Page Page Page Page $700.00 How To Read Shop DrawingsPrecaucion Warnung Limited Warranty