ACCESSORIESC-3

TYPICAL STITCH KEY PRESS

SEQUENCE

Spool screen is displayed prior to pressing Stitch key. Stitch key is pressed, Stitch timers are activated and the display changes to Stitch screen. Stitch ON and OFF timers can now be adjusted using the center and right arrow keys. Once the timers have been set, pressing the Stitch key again returns the display to the original Spool screen with the Stitch timer status indicated in the bottom left corner.

memory 4 is recalled and appears on the display. This whole cycle is repeatable as long as the unit remains in Toggle mode.

TOGGLE KEY

The first time this key is pressed it turns on toggle mode and recalls the setup in memo- ry 4. This mode allows you to toggle between the setups in memory 4 and mem- ory 5. Each time the key is pressed, it alter- nates between the two memories. The tog- gle screen displays the memory number the current setup was recalled from, indicates spool (SPOL:) mode, displays percentage of wire feed speed, and set arc voltage. The cursor underlines the memory number cur- rently selected.

TYPICAL TOGGLE KEY PRESS

SEQUENCE

Spool screen is displayed prior to pressing Toggle key. Toggle key is pressed, memory 4 is recalled and appears on the display. The unit is now in toggle mode. Pressing the Toggle key again “toggles” the unit, and

DISABLING SPOOL GUN

When the Spool Gun Adapter box transfer switch is set to FEEDER Gun position, the display will flash between these two mes- sages:

Pressing the Process key will return you to the last process entered before the Spool gun was attached.

IDEALARC SP-255

Image 31
Contents Idealarc SP-255 Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Master Table of Contents for ALL Sections Appendix Section DSection E Section FTechnical Specifications Idealarc SP-255 INSTALLATIONA-1Uncrating the SP-255 2INSTALLATIONSafety Precautions Input Power and Grounding ConnectionsGUN and Cable Installation INSTALLATIONA-3Output Polarity Connection Shielding GAS 4INSTALLATIONFumes and Gases can be dangerous OPERATIONB-1Limitations 2OPERATIONRecommended Processes and Equipment Welding CapabilityProcess WIRE/GAS KEY Start Mode SelectionsOPERATIONB-3 Typical Auto KEY Press Sequences Procedure Keys4OPERATION Auto KEYMemory Keys OPERATIONB-5Spot KEY Timer Keys6OPERATION Typical Memory Number KEY Press SequenceOPERATIONB-7 GUN Switch KeysTypical Toggle KEY Press Sequence 8OPERATIONTypical Activate KEY Press Sequence Using 4-STEP Trigger Interlock FunctionOPERATIONB-9 Step Trigger Interlock KeysWire Reel Loading GUN SwitchesWire Drive Roll Procedure for Changing Drive RollFeeding Electrode Idle Roll Pressure SettingOPERATIONB-11 To Start the Welder12OPERATION Making AN Auto Mode WeldOPERATIONB-13 Welding Thermal Overload Protection Wire Feed Overload ProtectionExplanation of Prompting and Error Messages 14OPERATIONOPERATIONB-15 Operation ACCESSORIESC-1 2ACCESSORIES Disabling Spool GUN ACCESSORIESC-3Idealarc SP-255 Routine Maintenance MAINTENANCED-1Safety Precautions Cable CleaningLiner Removal Replacement 2MAINTENANCEGUN Handle Disassembly MAINTENANCED-3Magnum 250SP GUN Parts and Accessories Idealarc SP-255 HOW to USE Troubleshooting Guide TROUBLESHOOTINGE-1Authorized Field Service Facility 2TROUBLESHOOTINGTroubleshooting Guide Problems Possible Areas Symptoms MisadjustmentsTROUBLESHOOTINGE-3 Authorized Field Service Facility 4TROUBLESHOOTINGContact your local Lincoln Function Problems TROUBLESHOOTINGE-5Contact your local Lincoln Authorized Field Service Facility 6TROUBLESHOOTINGSP-255 Wiring Diagram L9688 Dual Voltage Wiring DiagramsWiring Diagrams Dimension Print Page Page Page Page $700.00 How To Read Shop DrawingsPrecaucion Warnung Limited Warranty