Lincoln Electric SP-255 manual 2MAINTENANCE, Liner Removal Replacement

Page 34
FIGURE D.1
Liner trim length for the 250SP gun

D-2MAINTENANCE

5.Adjust the gas nozzle as appropriate for the GMAW process to be used. Typically, the contact tip end should be flush to .12" (3.2 mm) extended for the short-circuiting transfer process and .12" (3.2 mm) recessed for spray transfer.

LINER REMOVAL AND

REPLACEMENT

NOTE: Changing the liner for a different wire size requires replacement of the gas diffuser per the table below to properly secure the different liner.

 

 

 

Fixed

Adjustable

 

 

 

Nozzle Gas

Nozzle Gas

 

Replacement

Size Stencilled

Diffuser

Diffuser

Diameter of

Liner Part

on End of

Part No.

Part No.

Electrodes Used

Number

Liner Bushing

(and Stencil)

(and Stencil)

.025-.030" Steel

M16087-2

.030" (0.8 mm)

S19418-3

S19418-2

(0.6-0.8 mm)

 

 

 

 

.035-.045" Steel

M16087-1

.045" (1.2 mm)

S19418-3

S19418-1

(0.9-1.2 mm)

 

 

 

 

3/64" Aluminum

M16107-1

(Plastic Liner)

S19418-3

S19418-1

(1.2 mm)

 

 

 

 

 

 

 

 

 

LINER REMOVAL, INSTALLATION,

AND TRIMMING INSTRUCTIONS

FOR MAGNUM 250SP

NOTICE: The variation in cable lengths pre- vents the interchangeability of liners between guns. Once a liner has been cut for a particular gun, it should not be installed in another gun unless it can meet the liner cutoff length requirement. Liners are shipped with the jacket of the liner extended the proper

amount.

1.Remove the gas nozzle (and nozzle insulator, if used) to locate the set screw in the gas diffuser which is used to hold the old liner in place. Loosen the set screw with a 5/64" (2.0 mm) Allen wrench.

2.Remove the gas diffuser from the gun tube.

3.Lay the gun and cable

IDEALARC SP-255

out straight on a flat surface. Remove the liner nut from the Fast-Mate™ connector end of the cable and pull the liner out of the cable.

4.Insert a new untrimmed liner into the connector end of the cable. Be sure the liner busing is stencilled appropriately for the wire size being used.

5.Fully seat the liner bushing into the con- nector. finger tighten the liner nut onto the cable connector. The gas diffuser, at this time, should not be installed onto the end of the gun tube.

6.With the gas diffuser still removed from the gun tube, be sure the cable is straight, and then trim the liner to the length shown in Figure D.1. Remove any burrs from the end of the liner.

7.Screw the diffuser onto the end of the gun tube and securely tighten. Be sure the gas diffuser is correct for the liner being used. (see table left and diffuser stencil.)

8.Tighten the set screw in the side of the gas diffuser against the cable liner using a 5/64" (2.0 mm) Allen wrench.

CAUTION

This screw should only be gently tightened. Overtightening will split or collapse the liner and cause poor wire feeding.

Image 34
Contents Safety Depends on You Idealarc SP-255Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Master Table of Contents for ALL Sections Section F Section DSection E AppendixINSTALLATIONA-1 Technical Specifications Idealarc SP-255Input Power and Grounding Connections 2INSTALLATIONSafety Precautions Uncrating the SP-255GUN and Cable Installation INSTALLATIONA-3Output Polarity Connection 4INSTALLATION Shielding GASOPERATIONB-1 Fumes and Gases can be dangerousWelding Capability 2OPERATIONRecommended Processes and Equipment LimitationsProcess WIRE/GAS KEY Start Mode SelectionsOPERATIONB-3 Auto KEY Procedure Keys4OPERATION Typical Auto KEY Press SequencesOPERATIONB-5 Memory KeysTypical Memory Number KEY Press Sequence Timer Keys6OPERATION Spot KEYGUN Switch Keys OPERATIONB-78OPERATION Typical Toggle KEY Press SequenceStep Trigger Interlock Keys Using 4-STEP Trigger Interlock FunctionOPERATIONB-9 Typical Activate KEY Press SequenceProcedure for Changing Drive Roll GUN SwitchesWire Drive Roll Wire Reel LoadingTo Start the Welder Idle Roll Pressure SettingOPERATIONB-11 Feeding ElectrodeMaking AN Auto Mode Weld 12OPERATIONOPERATIONB-13 14OPERATION Wire Feed Overload ProtectionExplanation of Prompting and Error Messages Welding Thermal Overload ProtectionOPERATIONB-15 Operation ACCESSORIESC-1 2ACCESSORIES ACCESSORIESC-3 Disabling Spool GUNIdealarc SP-255 Cable Cleaning MAINTENANCED-1Safety Precautions Routine Maintenance2MAINTENANCE Liner Removal ReplacementGUN Handle Disassembly MAINTENANCED-3Magnum 250SP GUN Parts and Accessories Idealarc SP-255 TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments 2TROUBLESHOOTINGTroubleshooting Guide Authorized Field Service FacilityTROUBLESHOOTINGE-3 Authorized Field Service Facility 4TROUBLESHOOTINGContact your local Lincoln TROUBLESHOOTINGE-5 Function Problems6TROUBLESHOOTING Contact your local Lincoln Authorized Field Service FacilityWiring Diagrams SP-255 Wiring Diagram L9688 Dual VoltageWiring Diagrams Dimension Print Page Page Page Page How To Read Shop Drawings $700.00Precaucion Warnung Limited Warranty