Lincoln Electric R3R 500-I manual Accessories, Optional Equipment, K857 Remote Current Control

Page 11

C-1

ACCESSORIES

C-1

 

 

 

OPTIONAL EQUIPMENT

K857 – REMOTE CURRENT CONTROL

The K857 consists of a control box with 8.5 m (28 ft) of four conductor cable and a 6 pin Amphenol for easy connection to the front of the power source.

The K857 will give the same control as the current con- trol on the machine depending on the position of the current dial selector switch. (Current dial selector switch not used on the R3R 375-I.)

CAUTION

Extreme care must be observed when installing or extending the wiring of a remote control. The Remote Control cord can be lengthened to any length by splicing four wires to the standard 28 ft (8.5 m) cord before connecting to the R3R recep- tacle. Only the green lead can and should be grounded to the machine case.

K817, K817R – UNDERCARRIAGE

For easy moving of the machine, optional undercar- riages are available with either steel or rubber tire wheels.

K963 – HAND AMPTROL AND K870 FOOT AMPTROL

Connect directly to the 6 pin Amphenol on the front of the power source.

POCKET AMPTROL – (factory installed only)

The Pocket Amptrol option provides a remote current control for the R3R welders. This “wireless” control requires no control cable connection to the welder.

a.On the R3R 500-I andI R3R 600-I the welder Current Control (labeled “ “ switch must be in the Remote

( ) position and the Current Dial Selector switch

in the “B” range. The R3R 375-I has only one Current Dial Selector and no selector switch. With the Current Control switch in the Remote position, the current control potentiometer on the welder is removed from the circuit and its setting has no effect on the output. With the Current Dial Selector switch in the “B” range position, the Pocket Amptrol provides total control of the welder’s output.

b.Turn the welder power switch on.

c.Insert one end of the probe into the electrode hold- er and hold the other end on the work for approxi- mately five seconds.

AMMETER AND VOLTMETER – (factory installed only)

IDEALARC® R3R 375-I, 500-I AND 600-I

Image 11
Contents R3R 375-I, 500-I California Proposition 65 Warnings SafetyElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Duty Cycle InstallationInstallation Input Power ConnectionOperation Output Current Control Dial Output Current Control MACHINE- Remote SwitchHigh Temperature Warning Light ARC Force Control DialK817, K817R Undercarriage AccessoriesOptional Equipment K857 Remote Current ControlPocket Amptrol MaintenanceRoutine Maintenance Power Rectifier ReplacementHOW to USE Troubleshooting Guide TroubleshootingRecommended Function Problems Troubleshooting Troubleshooting Problems Possible Cause Recommended 375 R3RChecking Snubber Circuit Troubleshooting ProceduresChecking Current Control Rheostat on Machine Diagram Power Diode Test Power Silicon Controlled REC- Tifier TestIdealarc R3R-400, 500-I, 500 & 600-I Wiring Diagram Wiring DiagramsWiring Diagrams R3R 375-I, 500-I K817 or K817R Precaucion Aviso DE