Lincoln Electric R3R 375-I, R3R 500-I manual Troubleshooting

Page 16

E-4

 

TROUBLESHOOTING

 

E-4

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed througout this manual

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE CAUSE

 

RECOMMENDED

 

(SYMPTOMS)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

E. Machine does not have

1.

Input fuse blown. Machine is

1.

Replace fuse or repair input line.

maximum output (67 to 71 volts).

 

single phased.

 

Check reason for fault.

 

 

2.

One phase of main transformer

2.

Repair.

 

 

 

windings open.

 

 

 

 

3.

Defective power bridge.

3.

Check bridge per

 

 

 

 

 

Troubleshooting Procedures

 

 

 

 

 

Section J and check snubber per

 

 

 

 

 

Section F.

 

 

 

 

 

F. Machine comes on but soon trips

1.

Improper ventilation.

1.

Make sure all case openings are

off while under load and High

 

 

 

free for proper circulation of air.

Temperature Warning Light

 

 

 

 

glows. (Thermostat tripped)

2.

Loaded beyond rating.

2.

Operate at rated current and

 

 

 

 

 

duty cycle.

 

 

3.

Fan inoperative.

3.

Check leads and motor bearings.

 

 

 

 

 

Fan can be tested on 115 volt

 

 

 

 

 

line.

 

 

4.

Shorted diode or SCR in power

4.

Refer to Troubleshooting

 

 

 

rectifier bridge.

 

Procedures Section J and

 

 

 

 

 

Snubber, Section F.

 

 

 

 

 

G.Machine comes on but reduces

1.

Excessive load causing the over-

1.

Reduce load.

to low output under load and

 

load protection on control board

 

 

remains there until the load is

 

to operate.

 

 

broken and arc restarted. See

 

 

 

 

Fault Protection Troubleshooting

2.

Machine output shorted causing

2.

Turn machine off and remove

Section E.

 

overload protection on control

 

short.

 

 

 

board to operate.

 

 

 

 

3.

Control circuit defective.

3.

Replace per PC board,

 

 

 

 

 

Troubleshooting, Section A.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

IDEALARC® R3R 375-I, 500-I AND 600-I

Image 16
Contents R3R 375-I, 500-I Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation InstallationInput Power Connection Duty CycleOperation Output Current Control MACHINE- Remote Switch High Temperature Warning LightARC Force Control Dial Output Current Control DialAccessories Optional EquipmentK857 Remote Current Control K817, K817R UndercarriageMaintenance Routine MaintenancePower Rectifier Replacement Pocket AmptrolTroubleshooting HOW to USE Troubleshooting GuideRecommended Function Problems Troubleshooting Troubleshooting Problems Possible Cause Recommended R3R 375Troubleshooting Procedures Checking Snubber CircuitChecking Current Control Rheostat on Machine Power Silicon Controlled REC- Tifier Test Diagram Power Diode TestWiring Diagrams Idealarc R3R-400, 500-I, 500 & 600-I Wiring DiagramWiring Diagrams R3R 375-I, 500-I K817 or K817R Precaucion Aviso DE