Lincoln Electric R3R 375-I, R3R 500-I manual Recommended

Page 14

E-2

 

TROUBLESHOOTING

E-2

 

 

 

 

 

Observe all Safety Guidelines detailed througout this manual

 

 

 

 

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

A. Input contactor chatters.

1.Faulty input contactor.

1.Repair or replace.

 

 

2.Low line voltage.

2.Check with Power Company.

 

 

 

B. Machine input contactor does not

1.Supply line fuse blown.

1.Replace (look for reason for

operate.

 

blown fuse first).

 

 

2.Power circuit dead.

2.Check voltage.

 

 

3.Broken or loose power lead.

3.Repair.

 

 

4.Wrong voltage.

4.Check voltage against

 

 

 

instructions.

 

 

5.Thermostats tripped. (High

5.a. Make sure the fan is operating

 

 

Temperature Warning Light

and that there are no obstruc-

 

 

should be lit.) (Welder

tions to free flow of air.

 

 

overheated.)

b. Operate at normal current

 

 

 

and duty cycle.

 

 

 

c. Replace High Temperature

 

 

 

Warning Light if defective.

 

 

6.Input contactor coil open.

6.Replace.

 

 

7.Open winding on 115V pilot

7.Replace.

 

 

transformer.

 

 

 

8.Power ON-OFF switch not

8.Replace.

 

 

closing.

 

 

 

9.Lead broken or loose connec-

9.Replace.

 

 

tion in 115V starter circuit.

 

 

 

10.Thermostats defective. (High

10.Turn input power off (115V cir-

 

 

Temperature Warning Light

cuit is hot when input power is

 

 

should be lit.)

connected). Check thermostats

 

 

 

with continuity meter – should

 

 

 

read short-circuit when machine

 

 

 

is cool. Replace if defective.

 

 

 

There are two thermostats; one

 

 

 

on the secondary lead and one

 

 

 

on the choke. Replace High

 

 

 

Temperature Warning Light if

 

 

 

defective.

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

IDEALARC® R3R 375-I, 500-I AND 600-I

Image 14
Contents R3R 375-I, 500-I Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Input Power Connection InstallationInstallation Duty CycleOperation ARC Force Control Dial Output Current Control MACHINE- Remote SwitchHigh Temperature Warning Light Output Current Control DialK857 Remote Current Control AccessoriesOptional Equipment K817, K817R UndercarriagePower Rectifier Replacement MaintenanceRoutine Maintenance Pocket AmptrolTroubleshooting HOW to USE Troubleshooting GuideRecommended Function Problems Troubleshooting Troubleshooting Problems Possible Cause Recommended R3R 375Troubleshooting Procedures Checking Snubber CircuitChecking Current Control Rheostat on Machine Power Silicon Controlled REC- Tifier Test Diagram Power Diode TestWiring Diagrams Idealarc R3R-400, 500-I, 500 & 600-I Wiring DiagramWiring Diagrams R3R 375-I, 500-I K817 or K817R Precaucion Aviso DE