| TROUBLESHOOTING |
| |||
|
|
|
|
|
|
| Observe all Safety Guidelines detailed througout this manual | ||||
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE CAUSE |
| RECOMMENDED |
| (SYMPTOMS) |
|
| COURSE OF ACTION | |
|
|
|
| ||
|
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
|
|
|
| |
C. Machine input contactor closes | 1. | Electrode or work lead loose or | 1. | Repair connections. | |
but has no or low output. Open |
| broken. |
|
| |
circuit voltage should be 67 to 71 |
|
|
|
| |
volts. | 2. | Open transformer primary or | 2. | Repair. | |
|
|
| secondary circuit. |
|
|
|
| 3. | Supply line fuse blown. | 3. | Replace blown fuse – check fuse |
|
|
|
|
| size. |
|
| 4. | Input line grounded causing | 4. | Repair input to machine. |
|
|
| single phase input. |
|
|
|
| 5. | Input leads not connected to | 5. | Connect input lead. |
|
|
| contactor. |
|
|
|
| 6. | Latching resistor, R3, open. | 6. a. Replace. | |
|
|
|
|
| b. Check leads to the resistor |
|
|
|
|
| and repair if defective. |
|
| 7. | Control circuit problems. | 7. | See Troubleshooting Procedures |
|
|
|
|
| – Power Silicon Controlled |
|
|
|
|
| Rectifier. |
|
|
|
|
| |
D. Machine has maximum output | 1. | Possible defective power SCR. | 1. | Remove all gate leads G1, G2 | |
but no control. |
|
|
| and G3 at PC board connector | |
|
|
|
|
| J4. If welder has any open circuit |
|
|
|
|
| voltage, power SCR is defective. |
|
|
|
|
| See Troubleshooting Procedures |
|
|
|
|
| Section J. |
|
| 2. | Possible defective control board. | 2. See PC board Troubleshooting | |
|
|
|
|
| Procedures Section A |
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
IDEALARC® R3R