Lincoln Electric R3R 500-I, R3R 375-I manual Troubleshooting

Page 17

E-5

 

TROUBLESHOOTING

 

E-5

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed througout this manual

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE CAUSE

 

RECOMMENDED

 

(SYMPTOMS)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

H. Machine trips off when under no

1. Power bridge rectifier may have

1.

Refer to Power Hybrid,

load or makes excessive noise

 

a shorted diode or SCR.

 

Troubleshooting Procedures,

like it is loaded.

 

 

 

Section J and Snubber, Section

 

 

 

 

 

F.

 

 

2.

Short in the transformer.

2.

Repair.

 

 

3.

Fan hitting vertical baffle.

3.

Clear the fan.

 

 

 

 

I. Variable or sluggish welding arc.

1. Poor work or electrode cable

1.

Check and clean cable connec-

 

 

 

connection.

 

tions.

 

 

2.

Current too low.

2.

Check recommended currents

 

 

 

 

 

for rod type and size.

 

 

3.

Welding leads too small.

3.

See Table in Output Connection

 

 

 

 

 

Section.

 

 

4.

Open SCR or diode in power

4.

Check per Power Rectifier

 

 

 

rectifier bridge.

 

Bridge Troubleshooting

 

 

 

 

 

Procedures, Section J and

 

 

 

 

 

Snubber, Section F.

 

 

5.

Control circuit problems.

5.

See SCR Troubleshooting,

 

 

 

 

 

Section K.

 

 

 

 

J. Welder will not shut off.

1. Input contactor contacts frozen.

1.

Replace input contactor.

 

 

 

 

K. Current control on machine not

1. Current control switch in wrong

1.

Place switch in “machine” ( I )

functioning.

 

position.

 

position.

 

 

2.

Current control switch defective.

2.

Check per Section H.

 

 

3.

Current control potentiometer

3.

Check per Section G.

 

 

 

defective.

 

 

 

 

4.

Lead or connection in control

4. Repair or connect.

 

 

 

circuit open.

 

 

 

 

5.

Defective control or circuit

5.

See SCR Troubleshooting,

 

 

 

boards.

 

Section K.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

IDEALARC® R3R 375-I, 500-I AND 600-I

Image 17
Contents R3R 375-I, 500-I California Proposition 65 Warnings SafetyElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation InstallationInput Power Connection Duty CycleOperation High Temperature Warning Light Output Current Control MACHINE- Remote SwitchARC Force Control Dial Output Current Control DialOptional Equipment AccessoriesK857 Remote Current Control K817, K817R UndercarriageRoutine Maintenance MaintenancePower Rectifier Replacement Pocket AmptrolHOW to USE Troubleshooting Guide TroubleshootingRecommended Function Problems Troubleshooting Troubleshooting Problems Possible Cause Recommended 375 R3RChecking Snubber Circuit Troubleshooting ProceduresChecking Current Control Rheostat on Machine Diagram Power Diode Test Power Silicon Controlled REC- Tifier TestIdealarc R3R-400, 500-I, 500 & 600-I Wiring Diagram Wiring DiagramsWiring Diagrams R3R 375-I, 500-I K817 or K817R Precaucion Aviso DE