TROUBLESHOOTING

TROUBLESHOOTING

Problem

Cause

Corrective Action

No TV reception on AIR

No 12VDC power at PCB

Check power and ground connections with test light

 

Blown Fuse

Check fuse in wall plate and main supply

 

Bad coax connection

Check to ensure cables are connected properly at TV & wall plate

 

Wall Plate Switch in wrong position

Move switch to AIR position

 

TV tuner not set to AIR

Check TV tuner status in on screen menu

LED Indicator is Off

No 12VDC power at PCB

Check power and ground connections with test light

 

Blown Fuse

Check fuse in wall plate and main supply

 

Shorted coax connection

Check Antenna coax connection for short

 

Switch in wrong position

Check switch position

No TV reception on Cable

No 12VDC power at PCB

Check power and ground connections with test light

 

Blown Fuse

Check fuse in wall plate and main supply

 

Bad coax connection

Check to ensure cables are connected properly at TV & wall plate

 

Wall Plate Switch in wrong position

Move switch to CABLE position

 

TV tuner not set to CABLE

Check TV tuner status in on screen menu

No power at DC socket

No 12VDC power at PCB

Check power and ground connections with test light

 

Blown Fuse

Check fuse in wall plate and main supply

For technical assistance, please visit www.asaelectronics.com