Lincoln Electric IM889-A Stopping the Engine, Welder Operation, Constant Current CC-STICK Welding

Page 23

B-5

OPERATION

B-5

 

 

 

NOTE: If the unit fails to start turn Run/Stop switch to off and repeat step 3 through step 7 after waiting 30 seconds.

CAUTION

Do not allow the starter motor to run continuously for more than 20 seconds.

Do not push the START button while the engine is running because this can damage the ring gear and/or the starter motor.

If the Engine Protection or Battery Charging Lights do “not” turn off shortly after starting the engine shut off the engine immediately and

determine the cause.

------------------------------------------------------------------------

NOTE: When starting for the first time, or after and extended period of time of not operating, it will take longer than normal to start because the fuel pump has to fill the fuel system. For best results, bleed the fuel system as indicated in Maintenance Section of this manual.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and allow the engine to run at low idle speed for a few minutes to cool the engine.

STOP the engine by placing the RUN-STOP switch in the STOP position.

NOTE: A fuel shut off valve is located on the fuel pre- filter.

WELDER OPERATION

DUTY CYCLE

Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example a 60% duty cycle, represents 6 minutes of load and 4 minutes of no load in a 10 minute period.

ELECTRODE INFORMATION

For any electrode the procedures should be kept with- in the rating of the machine. For information on elec- trodes and their proper application see (www.lincolnelectric.com) or the appropriate Lincoln publication.

The VANTAGE 400 (CE) can be used with a broad range of DC stick electrodes. The MODE switch provides two stick welding settings as follows:

The ARC CONTROL dial sets the short circuit current (arc-force) during stick welding to adjust for a soft or crisp arc. Increasing the number from -10(soft) to +10(crisp) increases the short circuit current and pre- vents sticking of the electrode to the plate while welding. This can also increase spatter. It is recommended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with the dial set at 0.

NOTE: Due to the low OCV with the VRD on, a very slight delay during striking of the electrodes may occur. Due to the requirement of the resis- tance in the circuit to be low for a VRD to operate, a good metal-to-metal contact must be made between the metal core of the electrode and the job. A poor connection anywhere in the welding output circuit may limit the operation of the VRD. This includes a good connection of the work clamp to the job. The work clamp should be connected as close as practical to where the welding will be per- formed.

A. For New Electrodes

E6010 - Touch, Lift to Start the Arc

E7018, E7024 - Touch, Rock Back and Forth in Joint, Lift .

Once the arc is started, normal welding technique for the application is then used.

B. For Re-Striking Electrodes

Some electrodes form a cone at the end of the electrode after the welding arc has been broken, particularly iron powder and low hydrogen elec- trodes. This cone will need to be broken off in order to have the metal core of the electrode make con- tact.

E6010 - Push, Twist in Joint, Lift

E7018, E7024 - Push, Rock Back and Forth in

Joint, Lift.

Once the arc is started, normal welding technique for the application is then used.

For other electrodes the above techniques should be tried first and varied as needed to suit operator preference. The goal for successful starting is good metal to metal contact.

For indicator light operation, see table B.1.

CONSTANT CURRENT (CC-STICK) WELDING

DOWNHILL PIPE Welding

The CC-STICK position of the MODE switch is designed for horizontal and vertical-up welding with all types of electrodes, especially low hydrogen. The OUTPUT CON- TROL dial adjusts the full output range for stick welding.

This slope controlled setting is intended for "out-of- position" and "down hill" pipe welding where the oper- ator would like to control the current level by changing the arc length.

VANTAGE® 400 (CE)

Image 23
Contents Vantage California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents 528 Section DSection E Section FInstallation K2502-1, -3 UK K2502-2, -4 Europe Model NumbersLocation and Ventilation Safety PrecautionsVRD Voltage Reduction Device Towing PRE-OPERATION Engine ServiceHigh Temperature Operation Vehicle MountingFuel Battery ConnectionRemote Control OILTotal Combined Length of Electrode and Work Cables Electrical ConnectionsMachine Grounding Welding Output CablesAcross The-Arc Model Auxiliary PowerStandby Power Connections Connection of Lincoln Electric Wire Feeders8INSTALLATIONA-8 General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchTable B.2 Typical Vantage 400 CE Fuel Consumption Engine ControlsGlow Plug Push Button Circuit Breaker Starting the EngineDuty Cycle Stopping the EngineWelder Operation Constant Current CC-STICK WeldingTable B.3 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 MAX Table B.6 Wire WELDING-CVARC Gouging Table B.4TIG Options AccessoriesField Installed Options / Accessories Wire Feeder OptionsRoutine Maintenance MaintenanceOIL Filter Change AIR CleanerEngine OIL Change Servicei Instructions Bleeding the Fuel System Cooling SystemTightening the FAN Belt Arrestor Engine AdjustmentBattery Maintenance Servicing Optional SparkWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingContact Your local Lincoln Authorized Field Service FacilityWelding without a control cable Troubleshooting Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams Vantage WiringDiagram Vantage 400 CE UK Wiring Diagram Codes 11296Vantage 400 CE Euro Wiring Diagram Codes 11297 L12964 Dimension PrintVantage 400 CE Vantage 400 CE Precaucion Warnung