INSTALLATION | ||
|
|
|
c.Attach the single lead from the front of the
d.Set the “RANGE” switch to a suitable position.
e.Place the Engine switch in the “Auto Idle” position.
f.Set the Welding Mode on the
g.Adjust the wire feed speed at the
Note:
CONNECTION OF THE LN-25 TO THE
EAGLE 10,000
a.Shut the welder off.
b.For electrode Positive, connect the electrode cable from the
c.Position the “RANGE” switch to a suitable posi- tion.
d.Attach the single lead from the
e.Place the engine switch in the “AUTO IDLE” posi- tion.
f.Set the Wire Feed Mode switch on the
g.Adjust wire feed speed at the
Note: The welding electrode is energized at all times, unless an
CONNECTION OF K930-2 TIG MODULE TO THE EAGLE 10,000.
The TIG Module is an accessory that provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding. The Eagle 10,000 cannot weld in AC, but the
Note: The TIG Module does not require the use of a high frequency bypass capacitor. However, if the EAGLE 10,000 is used with any other high frequency equipment, the bypass capacitor must be installed, order kit T12246.
INSTRUCTIONS
ADDITIONAL SAFETY PRECAUTIONS
Always operate the welder with the roof and case sides in place as this provides maximum protection from moving parts and assures proper cooling air flow.
Read and understand all Safety Precautions before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Owner’s Manual.
WELDER OPERATION
WELDER OUTPUT
•Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS.
•Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example, a 60% duty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minute period. Duty Cycle for the EAGLE 10,000 is 100%.
EAGLE 10,000
Constant Current | 210 Amps DC @ 25 Volts |
|
|
AUXILIARY POWER
The EAGLE 10,000 can provide, up to 10,000 watts of 120/240 volts AC, single phase 60Hz power peak use and up to 9,000 watts of 120/240 volts AC, single phase 60Hz power for continuous use. The front of the machine includes three receptacles for connecting the AC power plugs; one 50 amp 120/240 volt NEMA
CAUTION
Do not connect any plugs that connect to the power receptacles in parallel.
Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to
10.Voltage is now correct at the receptacles for auxil- iary power.
EAGLE 10,000