OPERATION

B-3

 

 

 

STARTING/SHUTDOWN INSTRUCTIONS

STARTING THE ENGINE

WARNING

Do not touch electrically live parts of electrode with skin or wet clothing.

Keep flammable material away.

Insulate yourself from work and

ground. Wear eye, ear, and body protection.

• Keep your head out of the fumes.

• Use ventilation or exhaust to remove fumes from breathing zone.

Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner’s Manual before starting for the frist time.

Remove all loads connected to the AC power recepta- cles. Use the choke control as follows:

KOHLER ENGINE - Always pull the choke control out when starting the engine; cold, warm or hot.

Turn the engine switch to the “start” position and crank the engine until it starts. Release the switch as soon as the engine starts, slowly return the choke control to the full “in” position (choke open),

and turn the switch to the Auto Idle( / ) position. Do not turn the switch to the “start” position while the engine is running because this will cause damage to the ring gear and/or starter motor

After running at high engine speed for 10-14 seconds, the engine will go to low idle.

Allow the engine to warm up by letting it run at low idle for a few minutes.

STOPPING THE ENGINE

Remove all welding and auxiliary power loads and allow engine to run at low idle speed for a few minutes to cool the engine.

Stop the engine by placing the Engine switch in the

“OFF” position.

A fuel shut off valve is not required on the EAGLE 10,000 because the fuel tank is mounted below the engine.

BREAK-IN PERIOD

It is normal for any engine to use a greater amount of oil until the break-in is accomplished. Check the oil level twice a day during the break-in period (approxi- mately 50 running hours).

IMPORTANT: IN ORDER TO ACCOMPLISH THIS BREAK-IN, THE UNIT SHOULD BE SUBJECTED TO MODERATE LOADS, WITHIN THE RATING OF THE MACHINE. AVOID LONG IDLE RUNNING PERIODS. REMOVE LOADS AND ALLOW ENGINE TO COOL BEFORE SHUTDOWN.

The engine manufacturer’s recommendation for the running time until the first oil change is as follows:

KOHLER

CH20S

5 HRS

The oil filter is to be changed at the second oil change. Refer to the Engine Owner’s Manual or Maintenance section of this manual for more informa- tion.

EAGLE 10,000

Image 19
Contents 10,000 California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Eagle 10,000 K2343-1 InstallationHeight Width Depth Weight Towing Safety PrecautionsMachine Grounding Spark ArresterFuel Battery ConnectionsVehicle Mounting Welding Output CablesLifting Additional Safety PrecautionsConnection of Lincoln Electric Wire Feeders Angle of OperationInstructions Auxiliary PowerWelder Operation Eagle 10,000 Extension Cord Length Recommendations 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Motor StartingType Common Electrical Devices Possible Concerns Electrical Device USE with the Eagle 10,000Simultaneous Welding and Power Auxiliary Power While WeldingStandby Power Connections Connection of Eagle 10,000 to Premises Wiring Welder Controls Function and Operation Engine SwitchOperation General DescriptionControl Dial Range Switch20 H.P. Command Eagle 10,000 Approximate Fuel ConsumptionStopping the Engine STARTING/SHUTDOWN InstructionsBREAK-IN Period Starting the EngineTIG Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Stick Constant Current WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 K1745-1 GAS Cylinder Holder AccessoriesStick Wire FeedRecommended Equipment Plasma CuttingEngine OIL Change MaintenanceSafety Precautions Routine MaintenanceOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Eagle 10,000 Kohler CSA DiagramsEagle 10,000 / LN-25 Across the ARC Connection Diagram Eagle Eagle 10,000Eagle 10,000 Precaucion Warnung