AUXILIARY POWER WHILE WELDING

Simultaneous welding and power loads are permitted by following Table I. The permissible currents shown assume that current is being drawn from either the 120V or 240V supply (not both at the same time). Also, the “Output Control” is set at “10” for maximum auxiliary power.

TABLE I

SIMULTANEOUS WELDING AND POWER

Output Selector

Permissible Power

Permissible Auxiliary

 

Setting

Watts (Unity Power

Current in Amperes

 

Factor)

@ 120V *-or- @ 240V

 

 

 

 

 

Max. Stick or Wire

 

 

 

 

Feed Setting

None

0

0

 

 

 

 

 

 

145 Stick Setting

3950

32

16

 

 

 

 

 

 

90 Stick Setting

6000

50**

25

 

 

 

 

 

 

NO WELDING

9000

76**

38

 

 

 

 

 

 

*Each duplex receptacle is limited to 20 amps.

**Not to exceed 40A per 120VAC branch circuit when

splitting the 240 VAC output.

STANDBY POWER CONNECTIONS

The EAGLE 10,000 is suitable for temporary, standby, or emergency power using the engine manufacturer’s recommended maintenance schedule.

The EAGLE 10,000 can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service.

WARNING

(Connections must be made by a licensed electri- cian who can determine how the 120/240V power can be adapted to the particular installation and comply with all applicable electrical codes.) The following information can be used as a guide by the electrician for most applications (refer also to the connection diagram shown in Figure 1.)

-------------------------------------------------------------------------

1.Install a double pole, double throw switch between the power company meter and the premises disconnect.

Switch rating must be the same or greater than the customer’s premises disconnect and service overcurrent protection.

2.Take necessary steps to assure load is limited to the capacity of the EAGLE 10,000 by installing a 38 amp 240V double pole circuit breaker.

Maximum rated load for the 240V auxiliary is 38 amperes. Loading above 38 amperes will reduce output voltage below the allowable -10% of rated voltage which may damage appliances or other motor-driven equipment.

3.Install a 50 amp 120/240V plug (NEMA type 14-50) to the Double Pole Circuit Breaker using No. 8,

4 conductor cable of the desired length. (The

50 amp 120/240V plug is available in the optional plug kit.)

4.Plug this cable into the 50 amp 120/240V receptacle on the EAGLE 10,000 case front.

EAGLE 10,000

Image 15
Contents 10,000 California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Installation Technical Specifications Eagle 10,000 K2343-1Height Width Depth Weight Towing Safety PrecautionsMachine Grounding Spark ArresterFuel Battery ConnectionsVehicle Mounting Welding Output CablesLifting Additional Safety PrecautionsConnection of Lincoln Electric Wire Feeders Angle of OperationAuxiliary Power InstructionsWelder Operation Eagle 10,000 Extension Cord Length Recommendations 120/240 Volt Dual Voltage ReceptacleDuplex Receptacles Motor StartingType Common Electrical Devices Possible Concerns Electrical Device USE with the Eagle 10,000Auxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections Connection of Eagle 10,000 to Premises Wiring Welder Controls Function and Operation Engine SwitchOperation General DescriptionControl Dial Range Switch20 H.P. Command Eagle 10,000 Approximate Fuel ConsumptionStopping the Engine STARTING/SHUTDOWN InstructionsBREAK-IN Period Starting the EngineTIG Constant Current Welding Wire Feed Welding Processes Constant VoltageWelding Process Stick Constant Current WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 K1745-1 GAS Cylinder Holder AccessoriesStick Wire FeedRecommended Equipment Plasma CuttingEngine OIL Change MaintenanceSafety Precautions Routine MaintenanceOIL Filter Change AIR Cleaner and Other MaintenanceEngine Adjustments HOW to USE Troubleshooting Guide TroubleshootingTroubleshooting Troubleshooting Eagle 10,000 Kohler CSA DiagramsEagle 10,000 / LN-25 Across the ARC Connection Diagram Eagle Eagle 10,000Eagle 10,000 Precaucion Warnung