TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
TROUBLESHOOTING GUIDE
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS | POSSIBLE AREAS OF |
| RECOMMENDED | ||
(SYMPTOMS) | MISADJUSTMENT(S) |
| COURSE OF ACTION | ||
| OUTPUT PROBLEMS |
| |||
Thermal LED is lit. | 1. Fan thermostat has opened. |
| |||
| Check for proper fan operation. |
| |||
| (Fan should run whenever out- |
| |||
| put power is on.) Check for |
| |||
| material blocking intake or |
| |||
| exhaust louvers, or for excessive |
| |||
| dirt clogging cooling channels in |
| |||
| machine. Blow air in rear louvers |
| |||
| to remove dirt around the fan. |
| |||
| 2. Secondary rectifier or Choke |
| |||
| thermostat has opened. After |
| |||
| machine has cooled, reduce |
| |||
| load, duty cycle, or both. Check |
| |||
| for material blocking intake or |
| |||
| exhaust louvers. |
|
|
| |
| 3. DC Bus PC board thermostat |
| |||
| has opened check for excessive |
| |||
| load on 40VDC supply. |
|
| ||
|
|
| |||
Machine won’t weld, can’t get any | 1. Input voltage is too low or too | If all recommended possible areas | |||
output. | high. Make certain that input | ||||
| voltage is proper, according to | of misadjustments have been | |||
| the Rating Plate located on the | checked and the problem persists, | |||
| rear of the machine. |
| contact your local Lincoln | ||
| 2. If the Thermal LED is also lit, | Authorized Field Service Facility. | |||
| see “Yellow Thermal LED is Lit” |
| |||
| section. |
|
|
| |
| 3. Primary current limit has been |
| |||
| exceeded. Possible short in out- |
| |||
| put circuit. Turn machine off. |
| |||
| Remove all loads from the out- |
| |||
| put of the machine. Turn back |
| |||
| on. If condition persists, turn |
| |||
| power off, and contact an autho- |
| |||
| rized | Lincoln | Electric | Field |
|
| Service facility. |
|
|
| |
| 4. This problem will normally be |
| |||
| accompanied by an error code. |
| |||
| Error codes are displayed as a |
| |||
| series of red and green flashes by |
| |||
| the | status | light. | See |
|
| "Troubleshooting the Power Wave |
|
/Power Feed System Using the Status LED" section of this text.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.