PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

OUTPUT PROBLEMS

 

Thermal LED is lit.

1. Fan thermostat has opened.

 

 

Check for proper fan operation.

 

 

(Fan should run whenever out-

 

 

put power is on.) Check for

 

 

material blocking intake or

 

 

exhaust louvers, or for excessive

 

 

dirt clogging cooling channels in

 

 

machine. Blow air in rear louvers

 

 

to remove dirt around the fan.

 

 

2. Secondary rectifier or Choke

 

 

thermostat has opened. After

 

 

machine has cooled, reduce

 

 

load, duty cycle, or both. Check

 

 

for material blocking intake or

 

 

exhaust louvers.

 

 

 

 

3. DC Bus PC board thermostat

 

 

has opened check for excessive

 

 

load on 40VDC supply.

 

 

 

 

 

Machine wont weld, cant get any

1. Input voltage is too low or too

If all recommended possible areas

output.

high. Make certain that input

 

voltage is proper, according to

of misadjustments have been

 

the Rating Plate located on the

checked and the problem persists,

 

rear of the machine.

 

contact your local Lincoln

 

2. If the Thermal LED is also lit,

Authorized Field Service Facility.

 

see Yellow Thermal LED is Lit

 

 

section.

 

 

 

 

3. Primary current limit has been

 

 

exceeded. Possible short in out-

 

 

put circuit. Turn machine off.

 

 

Remove all loads from the out-

 

 

put of the machine. Turn back

 

 

on. If condition persists, turn

 

 

power off, and contact an autho-

 

 

rized

Lincoln

Electric

Field

 

 

Service facility.

 

 

 

 

4. This problem will normally be

 

 

accompanied by an error code.

 

 

Error codes are displayed as a

 

 

series of red and green flashes by

 

 

the

status

light.

See

 

 

"Troubleshooting the Power Wave

 

/Power Feed System Using the Status LED" section of this text.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 405

Image 33
Contents Power Wave Power Wave SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents Technical Specifications Power Wave InstallationSelect Suitable Location Safety PrecautionsOutput CABLES, Connections and Limitations Negative Electrode PolarityVoltage Sensing Table A.1 Work Voltage SensingElectrode Voltage Sensing System Model System DescriptionSystem SET-UP 6INSTALLATIONA-6Basic Rules Simple SystemMultiple Group System No FH0 AlllowedSingle Group Multi-Head System Single Group Multi-Head System Alternate Method Figure A.5Welding with Multiple Power Waves Control Cable SpecificationsTWO Power Waves Receptacle Specifications DIP Switch Settings and LocationsControl Board DIP Switch General Description OperationRecommended Processes and Equipment Recommended ProcessesLimitations Required EquipmentDuty Cycle and Time Period Case Front ControlsNominal Procedures Case Front Layout Power WaveFringe Procedures Welding AdjustmentsConstant Voltage Welding Welding ModeVolts / Trim ARC ControlPULSE-ON-PULSE GMAW-PP Pulse WeldingBenefits of Pulse on Pulse from Lincoln Electric Welding Procedures for PULSE-ON-PULSE Table B.2TIG Gtaw SmawRecommended Welding Procedures for Power Mode Table B.3 Power ModeFactory Installed AccessoriesField Installed Optional EquipmentMaintenance Capacitor Discharge ProcedureAlways wear a face shield and long sleeves when servicing HOW to USE Troubleshooting Guide TroubleshootingError code before the machine is turned off Using the Status LED to Troubleshoot System ProblemsError Code # Indication Error Codes for the PowerwaveTroubleshooting Guide Authorized Field Service FacilityContact your local Lincoln Problems Possible Areas Recommended Symptoms Troubleshooting Troubleshooting Diagrams Connection Diagram Semi-automatic Simple System Connection DiagramDimension Print Precaucion Warnung