ELECTROMAGNETIC COMPATIBILITY (EMC)

The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.

Methods of Reducing Emissions

Mains Supply

Welding equipment should be connected to the mains supply according to the manufacturer s recommendations. If interference occurs, it may be necessary to take additional precautions such as filtering of the mains supply. Consideration should be given to shielding the supply cable of permanently installed welding equipment, in metallic conduit or equivalent. Shielding should be electrically continuous throughout its length. The shielding should be connected to the welding power source so that good electrical contact is maintained between the conduit and the welding power source enclosure.

Maintenance of the Welding Equipment

The welding equipment should be routinely maintained according to the manufacturer s recommendations. All access and service doors and covers should be closed and properly fastened when the welding equipment is in operation. The welding equipment should not be modified in any way except for those changes and adjustments covered in the manufacturers instructions. In particular, the spark gaps of arc striking and stabilizing devices should be adjusted and maintained according to the manufacturer s recommendations.

Welding Cables

The welding cables should be kept as short as possible and should be positioned close together, running at or close to the floor level.

Equipotential Bonding

Bonding of all metallic components in the welding installation and adjacent to it should be considered. However, metallic components bonded to the work piece will increase the risk that the operator could receive a shock by touching these metallic components and the electrode at the same time. The operator should be insulated from all such bonded metallic components.

Earthing of the Workpiece

Where the workpiece is not bonded to earth for electrical safety, not connected to earth because of its size and position, e.g., ships hull or building steelwork, a connection bonding the workpiece to earth may reduce emissions in some, but not all instances. Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to users, or damage to other electrical equipment. Where necessary, the connection of the workpiece to earth should be made by a direct connection to the workpiece, but in some countries where direct connection is not permitted, the bonding should be achieved by suitable capacitance, selected according to national regulations.

Screening and Shielding

Selective screening and shielding of other cables and equipment in the surrounding area may alleviate problems of interference. Screening of the entire welding installation may be considered for special applications.1

1

Portions of the preceding text are contained in EN50199: "Electromagnetic Compatibility (EMC) product standard for arc welding equipment."

POWER WAVE 405

Image 7
Contents Power Wave Power Wave SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéElectromagnetic Compatibility EMC Safety Thank You Table of Contents Technical Specifications Power Wave InstallationSelect Suitable Location Safety PrecautionsNegative Electrode Polarity Output CABLES, Connections and LimitationsVoltage Sensing Work Voltage Sensing Table A.1Electrode Voltage Sensing System Model System DescriptionSimple System 6INSTALLATIONA-6System SET-UP Basic RulesNo FH0 Alllowed Multiple Group SystemSingle Group Multi-Head System Single Group Multi-Head System Alternate Method Figure A.5Control Cable Specifications Welding with Multiple Power WavesTWO Power Waves DIP Switch Settings and Locations Receptacle SpecificationsControl Board DIP Switch Recommended Processes OperationGeneral Description Recommended Processes and EquipmentCase Front Controls Required EquipmentLimitations Duty Cycle and Time PeriodWelding Adjustments Case Front Layout Power WaveNominal Procedures Fringe ProceduresARC Control Welding ModeConstant Voltage Welding Volts / TrimPULSE-ON-PULSE GMAW-PP Pulse WeldingSmaw Welding Procedures for PULSE-ON-PULSE Table B.2Benefits of Pulse on Pulse from Lincoln Electric TIG GtawRecommended Welding Procedures for Power Mode Table B.3 Power ModeOptional Equipment AccessoriesFactory Installed Field InstalledCapacitor Discharge Procedure MaintenanceAlways wear a face shield and long sleeves when servicing HOW to USE Troubleshooting Guide TroubleshootingError code before the machine is turned off Using the Status LED to Troubleshoot System ProblemsError Code # Indication Error Codes for the PowerwaveAuthorized Field Service Facility Troubleshooting GuideContact your local Lincoln Problems Possible Areas Recommended Symptoms Troubleshooting Troubleshooting Diagrams Connection Diagram Semi-automatic Simple System Connection DiagramDimension Print Precaucion Warnung