Lincoln Electric V300-PRO manual Remote Control Adapters, P O W E R S O U R C E

Page 22

REMOTE CONTROL ADAPTERS

 

T U R N T H E P O W E R S W I T C H O F T H E W E L D I N G P O W E R

 

S O U R C E " O F F " B E F O R E I N S T A L L I N G P L U G S O N C A B L E S

 

O R W H E N C O N N E C T I N G O R D I S C O N N E C T I N G P L U G S T O

 

W E L D I N G P O W E R S O U R C E .

S T R A I G H T P L U G ( 1 4 P I N )

C A B L E R E C E P T A C L E ( 6 S O C K E T )

T O P O W E R S O U R C E

 

 

T O : 1 ) K 8 5 7 R E M O T E C O N T R O L

 

2 ) K 9 6 3 H A N D A M P T R O L

K 8 6 4

3 ) K 8 7 0 F O O T A M P T R O L

 

22

 

 

C A B L E R E C E P T A C L E ( 1 4 S O C K E T )

 

T O : 1 ) L N - 7 W I R E F E E D E R S

S T R A I G H T P L U G ( 1 4 P I N )

 

T O P O W E R S O U R C E

 

K 8 7 6

C A B L E R E C E P T A C L E ( 6 S O C K E T )

 

 

T O : 1 ) L N - 2 5 W I R E F E E D E R S

 

4 - 1 9 - 9 6 D

 

S 1 9 3 0 9

Image 22
Contents INVERTECV300-PRO December,1999 Electric Shock can kill Electric and Magnetic Fields Précautions DE Sûreté Table of Contents Please Examine Carton and Equipment For Damage Immediately Installation SpecificationsProduct Description LN-25 Connection Instructions Single Phase InputThree Phase Input LN-7 Connection InstructionsParallel Operation Remote Control of InvertecK900-1 DC TIG Starter Connection Output Cables LN-9 GMA Connection InstructionsQuick Disconnect Plugs Operating Instructions Mode SwitchOFF Output Terminals Switch Arc Force / Inductance ControlAuxiliary Power MaintenanceMeter Polarity Switch Capacitor Discharge ProcedurePeriodic Maintenance TroubleshootingTroubleshooting Guide Trouble What To DoTest Procedures Next Test Step Check Result Conclusion Repair ActionNext Test Next Step Test Conclusion Repair Action Check Result Next Step Test Matched Parts Switch PC Board Replacement ProcedureTest After Repair Component to Heat Sink Replacement of Power Modules and Output DiodesPrinted Circuit Board Replacement Component Torque ±10%Remote Control Adapters P O W E R S O U R C EK867 Universal Adapter for 14-PIN Wire Feeder Receptacle Installation I N S T R U C T I O N SP U T C a B L E N T R O LP H E N O L R K E E N V E R T E C W E R S O U R C EP H E N O L R K A R E V E R T E C W E R S O U R C EN N E C T T O G E T H E R F O R L D I N G O U T P U T T U S E D O N I N V E R T E CM O T E O U T P U T C O N T R O L K876 Adapter to LN-25 Connection Diagram N T R O L C a B L EN D a M P T R O L E C T R O D E C a B L EP H E N O L X I L I a R Y P O W E R O T a M P T R O LK900-1 DC TIG Starter Connection Diagram R C HLN-9 GMA with K596 Cable to Invertec Connection Diagram E C T R O D E C a B L E Wiring Diagram V300-PRO Code 10256, V300-I Code + ARC ARCInvertec V300-PRO Invertec V300-PRO Invertec V300-PRO How To Read Shop Drawings $700.00Precaucion Warnung