CV FCAW This setting has been optimized for Innershield® and Outershield®
CV GMAW Short circuit, glob and spray transfer solid wire and gas welding are done in this mode. Low end procedures, less than 17V, may operate better in the FCAW mode. Voltage in the GMAW mode can become erratic when welding is attempted using voltages equal to or less than 17V DC+.
SMAW |
|
CRISP | FCAW |
SMAW |
|
SOFT | GMAW |
GTAW |
|
Output Terminals Switch
For processes and equipment that require energized machine terminals (stick, TIG,
Set to the REMOTE (OFF) position when using
ON
OUTPUT
TERMINALS
REMOTE
Arc Force / Inductance Control
This control functions in all modes except GTAW. For
CCmodes, this control acts as an Arc Force adjust- ment. The arc is soft at the minimum settings and more forceful or driving at the maximum settings. Higher spatter levels may be present at the maximum settings.
For CV modes, this control will set the degree of “pinch effect” which predominantly affects short circuit transfer. In FCAW, the maximum setting is generally preferred. With GMAW, the upper half of the range is preferred with CO2 or high content CO2 mixed. The lower half is for inert gas mixes.
Recommended Arc Force / Inductance Settings
For Selected Applications
Full Range Is
1 Is Very Soft, 10 Is Very Crisp
|
| Nominal | Recommended |
Mode | Process | Setting | Adjustment Range |
|
|
|
|
CC SMAW 1 | EXX18 thru | 5 | 1 (gentle, may stick) to 9 |
| EXX28 stick |
| (forceful, more spatter) |
|
|
|
|
CC SMAW 2 | EXX10 thru | 6 | 3 to 10 |
| EXX14 stick |
|
|
| Air Carbon Arc | 1 | None |
| Cutting |
|
|
|
|
|
|
CV FCAW | Innershield or | 10 | None |
| Outershield |
|
|
| Air Carbon Arc | 1 | None |
| Cutting |
|
|
|
|
|
|
CV GMAW* | CO2 or 25% CO2 | 7.5 | 5 to 10 |
| or similar |
|
|
| gas mixes |
|
|
| 98% | 5 | 1 to 10 |
| 90% |
|
|
| 2.5% CO2 and |
|
|
| other |
|
|
| predominantly |
|
|
| inert gases |
|
|
|
|
|
|
*1 = Lowest pinch, highest inductance and least spatter.
10 = Highest pinch, lowest inductance and most spatter.
– 12 – | – |