Lincoln Electric V300-PRO manual Next Step Test

Page 19

 

 

 

 

 

 

Next

 

 

Step

 

 

Test

 

Test

 

 

Test

Check

Result

Conclusion

Step

Repair Action

 

 

 

 

 

 

 

 

7

D13 Input

9 (pos) to H1 (neg)

>1K ohms

OK

cont

 

 

 

Rectifier

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (pos) to A (neg)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

9 (pos) to H5 (neg)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to H1 (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to A (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to H5 (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to H1 (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to A (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to H5 (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (pos) to H1 (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (pos) to A (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 ( pos) to H5 (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

Image 19
Contents INVERTECV300-PRO December,1999 Electric Shock can kill Electric and Magnetic Fields Précautions DE Sûreté Table of Contents Please Examine Carton and Equipment For Damage Immediately Installation SpecificationsProduct Description LN-7 Connection Instructions Single Phase InputThree Phase Input LN-25 Connection InstructionsParallel Operation Remote Control of InvertecK900-1 DC TIG Starter Connection Output Cables LN-9 GMA Connection InstructionsQuick Disconnect Plugs Operating Instructions Mode SwitchOFF Arc Force / Inductance Control Output Terminals SwitchCapacitor Discharge Procedure MaintenanceMeter Polarity Switch Auxiliary PowerTroubleshooting Periodic MaintenanceTrouble What To Do Troubleshooting GuideNext Test Step Check Result Conclusion Repair Action Test ProceduresNext Test Next Step Test Conclusion Repair Action Check Result Next Step Test Matched Parts Switch PC Board Replacement ProcedureTest After Repair Component Torque ±10% Replacement of Power Modules and Output DiodesPrinted Circuit Board Replacement Component to Heat SinkP O W E R S O U R C E Remote Control AdaptersInstallation I N S T R U C T I O N S K867 Universal Adapter for 14-PIN Wire Feeder ReceptacleE E N V E R T E C W E R S O U R C E N T R O LP H E N O L R K P U T C a B L EV E R T E C W E R S O U R C E P H E N O L R K A R EN N E C T T O G E T H E R F O R L D I N G O U T P U T T U S E D O N I N V E R T E CM O T E O U T P U T C O N T R O L N T R O L C a B L E K876 Adapter to LN-25 Connection DiagramX I L I a R Y P O W E R O T a M P T R O L E C T R O D E C a B L EP H E N O L N D a M P T R O LR C H K900-1 DC TIG Starter Connection DiagramLN-9 GMA with K596 Cable to Invertec Connection Diagram E C T R O D E C a B L E Wiring Diagram V300-PRO Code 10256, V300-I Code ARC + ARCInvertec V300-PRO Invertec V300-PRO Invertec V300-PRO $700.00 How To Read Shop DrawingsPrecaucion Warnung