Lincoln Electric V300-PRO manual Troubleshooting Guide, Trouble What To Do

Page 15

TROUBLESHOOTING GUIDE

Trouble

 

What To Do

 

 

Not output but fan operates and meter is on.

Perform test steps 1A and 1B.

 

 

 

Poor welding, weld settings drift, or output power is

1.

Check front panel wiring and controls.

low.

2.

Replace Control PC Board.

 

 

Main fuses open or Switch PC boards overheated.

Perform test steps 4 and 5 for both Switch PC Boards

 

and 7.

 

 

Output turns on momentarily then switches off and

Perform test steps 3B, 4 and 5.

repeats. Machine is connected for 380 VAC or higher

 

 

input voltage.

 

 

 

 

OCV is normal (approx. 65-75V) but output power is

Perform test steps 4 and 5 for both Switch PC Boards.

low (less than 20V and 100A). Machine makes

 

 

squealing noise while under load. Machine is connect-

 

 

ed for 230 VAC, or lower, input voltage.

 

 

 

 

Open circuit voltage is 1-2 volts.

Perform test step 6.

 

 

 

Output control not functioning on remote control. Local

1.

Check remote control assembly.

control OK.

2.

Check S3, Local/Remote switch.

 

 

 

Machine does not produce more than 250A output

1.

Replace main fuse if blown.

when connected to 3 phase supply.

2.

Replace Protection PC Board.

 

3.

Replace Control PC Board.

 

4.

Perform test step 7.

 

 

Machine does not produce more than 200 A output

Normal operation.

while connected to 1 phase supply.

 

 

 

 

Machine operates OK at 230 VAC or lower. No output

Perform test step 2.

at 380 VAC or higher.

 

 

 

 

Poor EXX10 stick electrode (5P) performance. Arc

Check D6 and D12, L1 and L2.

“pops out”.

 

 

 

 

No output or reduced output the first time power is

Check reconnect panel - connections and fuse.

applied to the machine.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

15

Image 15
Contents INVERTECV300-PRO December,1999 Electric Shock can kill Electric and Magnetic Fields Précautions DE Sûreté Table of Contents Please Examine Carton and Equipment For Damage Immediately Specifications InstallationProduct Description LN-7 Connection Instructions Single Phase InputThree Phase Input LN-25 Connection InstructionsRemote Control of Invertec Parallel OperationK900-1 DC TIG Starter Connection LN-9 GMA Connection Instructions Output CablesQuick Disconnect Plugs Mode Switch Operating InstructionsOFF Arc Force / Inductance Control Output Terminals SwitchCapacitor Discharge Procedure MaintenanceMeter Polarity Switch Auxiliary PowerTroubleshooting Periodic MaintenanceTrouble What To Do Troubleshooting GuideNext Test Step Check Result Conclusion Repair Action Test ProceduresNext Test Next Step Test Conclusion Repair Action Check Result Next Step Test Switch PC Board Replacement Procedure Matched PartsTest After Repair Component Torque ±10% Replacement of Power Modules and Output DiodesPrinted Circuit Board Replacement Component to Heat SinkP O W E R S O U R C E Remote Control AdaptersInstallation I N S T R U C T I O N S K867 Universal Adapter for 14-PIN Wire Feeder ReceptacleE E N V E R T E C W E R S O U R C E N T R O LP H E N O L R K P U T C a B L EV E R T E C W E R S O U R C E P H E N O L R K A R ET U S E D O N I N V E R T E C N N E C T T O G E T H E R F O R L D I N G O U T P U TM O T E O U T P U T C O N T R O L N T R O L C a B L E K876 Adapter to LN-25 Connection DiagramX I L I a R Y P O W E R O T a M P T R O L E C T R O D E C a B L EP H E N O L N D a M P T R O LR C H K900-1 DC TIG Starter Connection DiagramLN-9 GMA with K596 Cable to Invertec Connection Diagram E C T R O D E C a B L E Wiring Diagram V300-PRO Code 10256, V300-I Code ARC + ARCInvertec V300-PRO Invertec V300-PRO Invertec V300-PRO $700.00 How To Read Shop DrawingsPrecaucion Warnung