PRODUCT DESCRIPTION
The Invertec
SPECIFICATIONS
Product | Ordering | Input AC | Rated DC Output | Input Amps at Rated DC Output | Output | Weight | Dimensions | ||||
Name | Information | Voltage | Amps/Volts/Duty Cycle |
|
|
|
| Range | with Gun | HxWxD | |
208 | 230 | 460 | 575 | ||||||||
|
|
|
| (continuous) | (net) |
| |||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
| 208/230/460 | 300A / 32V / 60%(1) | 48 | 43 | 24 |
|
|
|
| |
|
| 3 Phase | 250A / 30V / 100%(1) | 37 | 33 | 19 |
|
|
|
| |
|
| 60 Hz | 300A / 35/39/41V /60%(2) | 49 | 48 | 28 |
|
|
| 18.7*x10.8x | |
Invertec |
|
|
|
|
|
|
|
| 22.2” | ||
|
|
|
|
|
|
|
| ||||
V300- |
| 208/230/460 | 250A / 30V / 60%(1) | 69 | 62 | 38 |
| AMPS | 64 lbs. | (475x274x | |
PRO |
| 1 Phase | 160A / 28V / 100%(1) | 53 | 47 | 29 |
| (29 kg) | 564 mm) | ||
|
| 60 Hz | 250A / 37/41/43V / 60%(2) | 75 | 67 | 42 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
| * Includes | |
|
|
|
|
|
|
|
|
|
| ||
|
| 575 | 300A / 32V / 60%(1) |
|
|
| 20 |
|
| handle | |
| 3 Phase | 250A / 30V / 100%(1) |
|
|
| 16 |
|
|
| ||
|
| 60 Hz | 300A / 36V / 60%(2) |
|
|
| 22 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
(1 )NEMA Class I Rated Output / Based on a 10 min. Period .
(2 )Lincoln plus rating.
* Overall Height Including Handle, (16.4” (417mm without handle).
INSTALLATION
WARNING
ELECTRIC SHOCK can kill.
•Have an electrician install and service this equipment.
•Turn the input power off at the fuse box before working on equipment.
•Do not touch electrically hot parts.
LOCATION
The Invertec has been designed with many features to protect it from harsh environments. Even so, it is important that simple preventative measures are fol- lowed in order to assure long life and reliable opera- tion.
•The machine must be located where there is free circulation of clean air such that air movement into the sides and out the bottom and front will not be restricted. Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown of the Invertec.
•Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.
ELECTRICAL INSTALLATION
1.The Invertec should be connected only by a quali- fied electrician. Installation should be made in accordance with the U.S. National Electrical Code, all local codes and the information detailed below.
2.Single voltage, 575 VAC machines, can only be connected to 575 VAC. No internal reconnection for other input voltages is possible.
3.Initial 208 VAC and 230 VAC operation will require
avoltage panel setup, as will later reconnection back to 460 VAC:
a.Open the access panel on the right side of the machine.
b.For 208 or 230: Position the large switch to
For 460: Position the large switch to
c.Move the “A” lead to the appropriate terminal.
– 7 –