INSTALLATION

A-7

 

 

 

AUXILIARY POWER

The auxiliary power capacity is 16,500 watts Peak, 14,500 Watts Continuous of 50 Hz, three phase power. The auxiliary power capacity rating in watts is equivalent to volt-amperes at unity power factor. The max permissible current of the 400 VAC output is 22 amps. Output voltage is within ± 10% at all loads up to the rated capacity.

Single phase power is:

6,900 Watts Peak / 6,900 Watts Continuous, 50 Hz

230 Volts 1-Phase (Euro).

3,400 Watts Peak / 3,400 Watts Continuous, 50 Hz

230 Volts 1-Phase (UK).

3,400 Watts Peak / 3,400 Watts Continuous, 50 Hz

115 Volts 1-Phase (UK).

STANDBY POWER CONNECTIONS

The machine is suitable for temporary, standby or emergency power using the engine manufacturer’s recommended maintenance schedule.

The machine can be permanently installed as a standby power unit for 400 VAC, three phase, 21 amp service.

Connections must be made by a licensed electrician who can determine how the power can be adapted to the particular installation and comply with all applica- ble electrical codes.

Take necessary steps to assure load is limited to the capacity of the VANTAGE® 500 (CE).

WARNING

Only a licensed, certified, trained electrician should install the machine to a premises or resi- dential electrical system. Be certain that:

The installation complies with the National Electrical Code and all other applicable electri- cal codes.

The premises is isolated and no feedback into the utility system can occur. Certain laws require the premises to be isolated before the generator is linked to the premises. Check your

local requirements.

-----------------------------------------------------------------------

-

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

Connection of LN-15 to the VANTAGE® 500 (CE)

1.Shut the welder off.

2.For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For elec- trode Negative, connect the electrode cable to the "-" terminal of the welder and work cable to the "+" terminal of the welder.

3.Across The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON".

When the gun trigger is closed, the current sens- ing circuit will cause the VANTAGE® 500 (CE) engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

4.Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the "WELD TERMINALS" switch to

"REMOTELY CONTROLLED"

5.Set the MODE switch to the "CV-WIRE " position.

6.Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polari- ty being used.

7.Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

8.Set the "IDLE" switch to the "AUTO" position.

9.When the gun trigger is closed, the current sens- ing circuit will cause the VANTAGE® 500 (CE) engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.

VANTAGE® 500 (CE)

Image 17
Contents Vantage California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Electromagnetic Compatibility EMC Vii Table of Contents Section E Section DSection F 535AIR Cleaner Engine Idler Muffler Engine Protection InstallationHeight Width Depth Weight Lubrication Emissions Fuel System GovernorK2503-1, -3 UK K2503-2, -4 Europe Model NumbersLocation and Ventilation Safety PrecautionsVRD Voltage Reduction Device High Temperature Operation PRE-OPERATION Engine ServiceVehicle Mounting TowingRemote Control Battery ConnectionOIL FuelElectrical Connections Standby Power Connections Auxiliary PowerConnection of Lincoln Electric Wire Feeders Across The-Arc Model8INSTALLATIONA-8 General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchGlow Plug Push Button Engine ControlsCircuit Breaker Starting the Engine Table B.2 Typical Vantage 500 CE Fuel ConsumptionWelder Operation Stopping the EngineConstant Current CC-STICK Welding Duty CycleTable B.3 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 ARC Gouging Wire WELDING-CVField Installed Options / Accessories AccessoriesWire Feeder Options TIG OptionsRoutine Maintenance MaintenanceOIL Filter Change AIR CleanerEngine OIL Change 3MAINTENANCED-3 Service IInstructionsBleeding the Fuel System Cooling SystemTightening the FAN Belt Battery Maintenance Engine AdjustmentServicing Optional Spark ArrestorWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingContact Your local Lincoln Authorized Field Service FacilityWelding without a control cable Troubleshooting Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams 500 CE 5WIRING DIAGRAMF-5Vantage WiringDiagram Dimension Print Vantage 500 CE Vantage 500 CE Precaucion Warnung