SAFETY

vii

Electromagnetic Compatibility (EMC)

Conformance

Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln Electric equipment. It is designed for industrial and professional use.

Introduction

All electrical equipment generates small amounts of electromagnetic emission. Electrical emission may be transmitted through power lines or radiated through space, similar to a radio transmitter. When emissions are received by other equipment, electrical interference may result. Electrical emissions may affect many kinds of electrical equipment; other nearby welding equipment, radio and TV reception, numerical controlled machines, telephone systems, computers, etc. Be aware that interference may result and extra precautions may be required when a welding power source is used in a domestic establishment.

Installation and Use

The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions. If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as simple as earthing (grounding) the welding circuit, see Note. In other cases it could involve construction of an electromagnetic screen enclosing the power source and the work complete with associated input filters. In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome.

Note: The welding circuit may or may not be earthed for safety reasons according to national codes. Changing the earthing arrangements should only be authorized by a person who is compe- tent to access whether the changes will increase the risk of injury, e.g., by allowing parallel welding current return paths which may damage the earth circuits of other equipment.

Assessment of Area

Before installing welding equipment the user shall make an assessment of potential electromagnetic prob- lems in the surrounding area. The following shall be taken into account:

a)other supply cables, control cables, signaling and telephone cables; above, below and adjacent to the welding equipment;

b)radio and television transmitters and receivers;

c)computer and other control equipment;

d)safety critical equipment, e.g., guarding of industrial equipment;

e)the health of the people around, e.g., the use of pacemakers and hearing aids;

f)equipment used for calibration or measurement

g)the immunity of other equipment in the environment. The user shall ensure that other equipment being used in the environment is compatible. This may require additional protection measures;

h)the time of day that welding or other activities are to be carried out.

L10093 3-1-96H

Image 8
Contents Vantage Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Electromagnetic Compatibility EMC Vii Table of Contents Section D Section ESection F 535Installation AIR Cleaner Engine Idler Muffler Engine ProtectionHeight Width Depth Weight Lubrication Emissions Fuel System GovernorModel Numbers K2503-1, -3 UK K2503-2, -4 EuropeLocation and Ventilation Safety PrecautionsVRD Voltage Reduction Device PRE-OPERATION Engine Service High Temperature OperationVehicle Mounting TowingBattery Connection Remote ControlOIL FuelElectrical Connections Auxiliary Power Standby Power ConnectionsConnection of Lincoln Electric Wire Feeders Across The-Arc Model8INSTALLATIONA-8 Operation General DescriptionWeld Mode Selector Switch Figure B.1Wire Feeder Voltmeter Switch Table B.1Engine Controls Glow Plug Push ButtonCircuit Breaker Starting the Engine Table B.2 Typical Vantage 500 CE Fuel ConsumptionStopping the Engine Welder OperationConstant Current CC-STICK Welding Duty CycleTable B.3 TIG WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 Wire WELDING-CV ARC GougingAccessories Field Installed Options / AccessoriesWire Feeder Options TIG OptionsMaintenance Routine MaintenanceOIL Filter Change AIR CleanerEngine OIL Change Service IInstructions 3MAINTENANCED-3Bleeding the Fuel System Cooling SystemTightening the FAN Belt Engine Adjustment Battery MaintenanceServicing Optional Spark ArrestorWelder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideAuthorized Field Service Facility Contact Your local LincolnWelding without a control cable Troubleshooting Faulty control cable. Repair or Field Service Facility Your local Lincoln AuthorizedDiagrams Diagrams Diagrams Diagrams 5WIRING DIAGRAMF-5 500 CEVantage WiringDiagram Dimension Print Vantage 500 CE Vantage 500 CE Precaucion Warnung