WARNING

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

Always operate the welder with the hinged door closed and the side panels in place.

Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction Manual.

GENERAL DESCRIPTION

The VANTAGE® 500 (CE) is a diesel engine powered DC multi-process welding power source and AC power generator. The engine drives a generator that supplies three phase power for the DC welding circuit, single phase and Three Phase power for the AC auxil- iary outlets. The DC welding control system uses state of the art Chopper Technology CT for superior weld-

R

ing performance.

The VANTAGE® 500 (CE) is fitted with a selectable VRD(Voltage Reduction Device). The VRD operates in the CC-Stick mode reducing the OCV to <13 volts, increasing operator safety when welding is performed in environments with increased hazard of electric shock such as wet areas and hot, humid sweaty con- ditions.

FOR AUXILIARY POWER:

Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.

ENGINE OPERATION

Before Starting the Engine:

Be sure the machine is on a level surface.

Open side engine door and remove the engine oil dipstick and wipe it with a clean cloth. Reinsert the dipstick and check the level on the dipstick.

Add oil (if necessary) to bring the level up to the full mark. Do not overfill. Close engine door.

Check radiator for proper coolant level. (Fill if nec- essary).

See Engine Owner’s Manual for specific oil and coolant recommendations.

WARNING

ADD FUEL

• Stop engine while fueling.

• Do not smoke when fueling.

Keep sparks and flame away from tank.

Do not leave unattended while fueling.

DIESEL FUEL • Wipe up spilled fuel and allow can cause fire. fumes to clear before starting

engine.

Do not overfill tank, fuel expansion may cause over-

flow.

DIESEL FUEL ONLY-Low sulphur fuel or ultra low sulphur fuel in U.S.A. and Canada.

------------------------------------------------------------------------

• Remove the fuel tank cap.

Fill the tank. DO NOT FILL THE TANK TO THE POINT OF OVERFLOW.

Replace the fuel cap and tighten securely.

See Engine Owner’s Manual for specific fuel recom- mendations.

BREAK-IN PERIOD

The engine will use a small amount of oil during its “break-in” period. The break-in period is about 50 run- ning hours.

Check the oil every four hours during break-in. Change the oil after the first 50 hours of operation and every 200 hours thereafter. Change the oil filter at each oil change.

CAUTION

During break-in, subject the Welder to moderate loads. Avoid long periods running at idle. Before stopping the engine, remove all loads and allow the engine to cool several minutes.

------------------------------------------------------------------------

VANTAGE® 500 (CE)

Image 19
Contents Vantage California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Electromagnetic Compatibility EMC Vii Table of Contents 535 Section DSection E Section FLubrication Emissions Fuel System Governor InstallationAIR Cleaner Engine Idler Muffler Engine Protection Height Width Depth WeightK2503-1, -3 UK K2503-2, -4 Europe Model NumbersVRD Voltage Reduction Device Safety PrecautionsLocation and Ventilation Towing PRE-OPERATION Engine ServiceHigh Temperature Operation Vehicle MountingFuel Battery ConnectionRemote Control OILElectrical Connections Across The-Arc Model Auxiliary PowerStandby Power Connections Connection of Lincoln Electric Wire Feeders8INSTALLATIONA-8 General Description OperationFigure B.1 Weld Mode Selector SwitchTable B.1 Wire Feeder Voltmeter SwitchTable B.2 Typical Vantage 500 CE Fuel Consumption Engine ControlsGlow Plug Push Button Circuit Breaker Starting the EngineDuty Cycle Stopping the EngineWelder Operation Constant Current CC-STICK WeldingTypical Current Ranges 1 for Tungsten ELECTRODES2 TIG WeldingTable B.3 ARC Gouging Wire WELDING-CVTIG Options AccessoriesField Installed Options / Accessories Wire Feeder OptionsRoutine Maintenance MaintenanceEngine OIL Change AIR CleanerOIL Filter Change 3MAINTENANCED-3 Service IInstructionsTightening the FAN Belt Cooling SystemBleeding the Fuel System Arrestor Engine AdjustmentBattery Maintenance Servicing Optional SparkWelder / Generator Maintenance HOW to USE Troubleshooting Guide TroubleshootingContact Your local Lincoln Authorized Field Service FacilityWelding without a control cable Troubleshooting Faulty control cable. Repair or Your local Lincoln Authorized Field Service FacilityDiagrams Diagrams Diagrams Diagrams 500 CE 5WIRING DIAGRAMF-5Diagram WiringVantage Dimension Print Vantage 500 CE Vantage 500 CE Precaucion Warnung